Tecan and Siloam Biosciences Co-market New ELISA System

Published: Wednesday, September 12, 2012
Last Updated: Wednesday, September 12, 2012
Bookmark and Share
The system is based on Tecan’s Freedom EVO® liquid handling technology and the Siloam Biosciences’ OptiMax™ microplate.

It offers rapid, sensitive and specific chemifluorescence-based ELISA procedures using exceedingly small sample volumes. The speed, sensitivity and small sample requirements are achieved as a result of the unique microfluidic design of the Optimiser™ technology. All reactions, including analyte capture and detection, occur within an ~5 μl microfluidic reaction chamber. The unique microchannel geometry and small reaction volume favor rapid reaction kinetics. A typical assay requires only a 5 μl sample and each reaction step is completed within 10 to 20 minutes. With wash times, substrate incubations and read times accounted for, a typical Optimiser technology-based ELISA can be completed within two hours. Exploiting these rapid reaction kinetics on a microscale, coupled with microplate automation on the Freedom EVO workstation, allows for extremely high sensitivity or very fast assays.

Automating the process with the Freedom EVO workstation further enhances Optimiser ELISA efficiency and increases throughput. The Freedom EVO automatically loads analytes and reagents into the wells of the microfluidic microplate, and allows the robotic manipulation of multiple OptiMax microplates. Automation with the Freedom EVO offers distinct performance benefits, including improved pipetting precision at very low volumes, precise control of dispensing times allowing for short incubation cycles, precise operation of the repeat load process dramatically improving sensitivity, and increased productivity allowing the user to attend to other tasks while the instrument is in operation. A fully integrated read-out of the chemifluorescent signal is provided by Tecan’s Infinite® M200 microplate reader.

Kevin Moore, Head of Applications and Solutions at Tecan, said: “We are delighted to be working with Siloam Biosciences and are looking forward to bringing our customers a new option for running automated ELISAs using the very exciting new technology of microplate-based microfluidics.”

Aniruddha Puntambekar, Chief Operating Officer at Siloam Biosciences Inc., added: “Tecan’s automation systems enhance the performance of OptiMax automation plates and we are pleased to be able to offer improvements to ELISA users based on Tecan’s automation expertise. Together, our technologies provide significant advances to immunoassay testing that will benefit customers of both companies.”


Further Information

Join For Free

Access to this exclusive content is for Technology Networks Premium members only.

Join Technology Networks Premium for free access to:

  • Exclusive articles
  • Presentations from international conferences
  • Over 3,100+ scientific posters on ePosters
  • More than 4,500+ scientific videos on LabTube
  • 35 community eNewsletters


Sign In



Forgotten your details? Click Here
If you are not a member you can join here

*Please note: By logging into TechnologyNetworks.com you agree to accept the use of cookies. To find out more about the cookies we use and how to delete them, see our privacy policy.


Scientific News
The Rise of 3D Cell Culture and in vitro Model Systems for Drug Discovery and Toxicology
An overview of the current technology and the challenges and benefits over 2D cell culture models plus some of the latest advances relating to human health research.
Biosensor Detects Molecules Linked to Cancer, Alzheimer's and Parkinson's
Novel biosensor has been proven capable of detecting molecules associated with neurodegenerative diseases and some types of cancer.
New Device Could Improve Cancer Detection
UBC researchers develop a microfluidic device to capture circulating tumor cells.
Gut Model HuMiX Works Like the Real Thing
Developed by scientists at the Luxembourg Centre for Systems Biology, the “Human Microbial Cross-talk” model is representative of the actual conditions and processes that occur within our intestines.
'Kidney on a Chip' Facilitates Safer Drug Dosing
University of Michigan researchers have used a "kidney on a chip" device to mimic the flow of medication through human kidneys and measure its effect on kidney cells.
AACR 2016: Cancer Immunotherapy and Beyond
At this year's meeting there was a palpable buzz around subjects ranging from microbiomics to the tumor microenvironment and cancer vaccines, big data to in vitro and in vivo modeling and drug delivery (to name just a few).
Releasing Cancer Cells for Better Analysis
A new device developed at the University of Michigan could provide a non-invasive way to monitor the progress of an advanced cancer treatment.
Lab-on-a-Chip for Detecting Glucose
By integrating microfluidic chips with fiber optic biosensors, researchers in China are creating ultrasensitive lab-on-a-chip devices to detect glucose levels.
Soy Shows Promise as Natural Anti-Microbial Agent
Soy isoflavones and peptides may inhibit the growth of microbial pathogens that cause food-borne illnesses, according to a new study from University of Guelph researchers.
Soy Shows Promise as Natural Anti-Microbial Agent
Researchers from University of Guelph show that soy isoflavones and peptides could be used to reduce microbial contamination of food.
Scroll Up
Scroll Down
Skyscraper Banner

SELECTBIO Market Reports
Go to LabTube
Go to eposters
 
Access to the latest scientific news
Exclusive articles
Upload and share your posters on ePosters
Latest presentations and webinars
View a library of 1,800+ scientific and medical posters
3,100+ scientific and medical posters
A library of 2,500+ scientific videos on LabTube
4,500+ scientific videos
Close
Premium CrownJOIN TECHNOLOGY NETWORKS PREMIUM FOR FREE!