FLUOstar Omega - Multimode Microplate Reading with Ultra-fast UV/Vis Absorbance

Product Description
fluostar-omega.jpg

The FLUOstar Omega is a multimode microplate reader with an innovative UV/Vis absorbance spectrometer. This proprietary spectrometer is capable of capturing a full absorbance spectrum (220 to 1000 nm) at a 1 nm resolution in less than 1 second per well. With a spectrometer-based microplate reader, never worry about choosing wavelengths again. Full spectrum analysis greatly enhances all absorbance assays by ensuring the optimal wavelengths can always be chosen, even after measurements are over.

With full UV/Vis spectrum absorbance and sensitive filter based detection in all measurement modes, the FLUOstar Omega multimode microplate reader provides users with unmatched flexibility and sensitivity to perform any assay in any detection mode.

Applications include:

• Ca2+ measurements (e.g. Ca2+ flux with Fura-2, Indo-1, FLUO-3/4)
• Enzyme activity
• FRET/BRET assays
• Cell toxicity, proliferation and viability
• Protein and nucleic acid quantitation (e.g. Lowry, DNA, 260/280)
• Immunoassays, ELISA
• Luciferase, dual luciferase, BRET, DLReadyTM
• ORAC and ROS assays
• Fluorescent proteins, including FRET (e.g. CFP/YFP)
• TR-FRET assays, including HTRF® and LanthaScreen®
• AlphaScreen®/AlphaLISA® Assays

FLUOstar Omega microplate reader offers the following detection modes:

• Fluorescence Intensity - including FRET
• Time-Resolved Fluorescence - including DELFIA®
• TR-FRET - including HTRF® and LanthaScreen®
• AlphaScreen®/AlphaLISA®
• High-Performance Luminescence (flash and glow) - including BRET
• UV/Vis Absorbance - measurement of complete spectra or individual wavelengths

Additional features
Any FLUOstar Omega can have the following features: top and bottom microplate reading, multi-chromatic detection, well scanning, sixteen filter positions, expanded temperature control up to 65°C, plate shaking, gas vent connection, onboard injectors and much more.

Gas Control Capabilities
Using a proprietary Atmospheric Control Unit (ACU), the FLUOstar Omega independently controls both the O2 (1-19%) and CO2 (0-20%) gas concentrations within the microplate reader chamber.

Upgradeable
The FLUOstar Omega series has a modular design. It can be fully upgraded to the powerful POLARstar Omega, which can perform Simultaneous Dual Emission detection and fluorescence polarization/anisotropy.

Stacker and robot compatibility
For medium level throughput, the FLUOstar Omega can be equipped with a 50 plate Stacker with optional bar code reader. For even higher throughput, the FLUOstar Omega can be integrated into all existing robotic systems via DDE or ActiveX interface.

Software package
The FLUOstar Omega license-free software includes the Omega Reader Control and the MARS Data Analysis software. This highly intuitive software provides limitless possibilities for test set-up and data analysis, while also offering one-click, app-style application shortcuts for running routine tests and data analyses.
Product FLUOstar Omega - Multimode Microplate Reading with Ultra-fast UV/Vis Absorbance
Company BMG Labtech GmbH
Price Request a quote
More Information View company product page
Catalog Number Unspecified
Quantity Unspecified
Company Logo

BMG Labtech GmbH
Allmendgruen 8, 77799 Ortenberg Germany

Tel: +49 781 96968-0
Fax: +49 781 96968-67
Email: hts@bmglabtech.com



Scientific News
Improving Natural Killer Cancer Therapy
Vanderbilt University researchers discover transcription factor critical for NK cell expansion. Findings could lead to increased therapeutic efficacy.
Molecular Mechanism For Generating Specific Antibody Responses Discovered
Study could spur more ways to treat autoimmune disease, develop accurate vaccines.
Gut Microbiomes Of Infants Have An Impact On Autoimmunity
Exposure to pathogens early in life is beneficial to the education and development of the human immune system.
Understanding Female HIV Transmission
Glowing virus maps points of entry through entire female reproductive tract for first time.
COPD Linked to Increased Bacterial Invasion
Persistent inflammation in COPD may result from a defect in the immune system that allows airway bacteria to invade deeper into the lung.
Finding Factors That Protect Against Flu
A clinical trial examining the body’s response to seasonal flu suggests new approaches for evaluating the effectiveness of seasonal flu vaccines.
Vaccinations Are More Effective When Administered In The Morning
Research from the University of Birmingham shows that influenza vaccinations have more protective responses when administered in the morning.
Secrets of a Deadly Virus Family Revealed
Scripps Research scientists uncover the glycoprotein structure of LCMV. The findings could guide development of treatments for Lassa fever.
Cytokine Triggers Immune Response at Expense of Blood Renewal
Research highlights promise of Anti-IL-1 drugs to treat chronic inflammatory disease.
Reduced Immune Response Causes Flu Deaths in Older Adults
Yale study suggests that immune response to flu causes death in older people, not the virus.

SELECTBIO

SELECTBIO Market Reports
Go to LabTube
Go to eposters
 
Access to the latest scientific news
Exclusive articles
Upload and share your posters on ePosters
Latest presentations and webinars
View a library of 1,800+ scientific and medical posters
3,000+ scientific and medical posters
A library of 2,500+ scientific videos on LabTube
4,500+ scientific videos
Close
Premium CrownJOIN TECHNOLOGY NETWORKS PREMIUM FOR FREE!