Shimadzu’s New Triple Quadrupole LCMS-8040

Published: Friday, June 08, 2012
Last Updated: Thursday, June 07, 2012
Bookmark and Share
Combines ultra high speed with enhanced sensitivity for an expanded range of applications.

Shimadzu Scientific Instruments has introduced the LCMS-8040, a triple quadrupole mass spectrometer, which combines newly improved ion optics and collision cell technology with proprietary ultra-fast technologies.

This significantly expands the application range and ensures high-sensitivity, high-throughput analysis at lower levels of detection.

The LCMS-8040 features the world’s fastest polarity switching at 15 msec and a high-speed scanning rate of 15,000 u/sec for maximum analytical throughput.

The LCMS-8040 achieves MRM transition speeds up to 555 MRMs per second with UFsweeper™ II collision cell technology.

UFsweeper II features high-speed ion transport technology that maintains sensitivity and suppresses crosstalk, even for high-speed or simultaneous multi-components analyses.

The LCMS-8040 incorporates newly improved ion optics (UF-Lens™), which integrate two multi-pole RF ion guides, and UFsweeper II technology to provide higher multiple reaction monitoring (MRM) sensitivity.

A five-fold increase in sensitivity (reserpine, S/N ratio) has been achieved by improving ion focusing and minimizing ion losses between multi-pole lenses.

These improvements also yield higher sensitivity for scan mode measurements. The combination of speed and sensitivity expands the potential range of LC/MS/MS applications and makes the 8040 the ideal platform for Qual/Quant analysis.

LabSolutions LCMS software offers a variety of data processing features, including a Quantitation Browser, which processes multiple analytes, and a Data Browser, which allows users to analyze and compare multiple sets of data in the same window.

Users also can easily optimize MRM parameters with LabSolutions software by utilizing automated flow injection analysis.

For improved performance, Shimadzu provides a variety of method packages to eliminate the need for MRM determination and chromatographic method development.

Additionally, the LCMS-8040 features a robust, user-friendly interface; compatibility with LCMS-8030 MRM parameters for easy method transfer; and easy maintenance to ensure maximum instrument operation.


Further Information
Access to this exclusive content is for Technology Networks Premium members only.

Join Technology Networks Premium for free access to:

  • Exclusive articles
  • Presentations from international conferences
  • Over 2,500+ scientific posters on ePosters
  • More than 3,700+ scientific videos on LabTube
  • 35 community eNewsletters


Sign In



Forgotten your details? Click Here
If you are not a member you can join here

*Please note: By logging into TechnologyNetworks.com you agree to accept the use of cookies. To find out more about the cookies we use and how to delete them, see our privacy policy.

Related Content

Shimadzu Opens New Solution Center at North American HQ
New, innovative, 4,100-square-foot facility now open to customers.
Saturday, February 08, 2014
Shimadzu Corporation Names New Director and President of SSI
Shuzo Maruyama appointed as president of Shimadzu Scientific Instruments.
Thursday, March 22, 2012
Scientific News
Structural Discoveries Could Aid in Better Drug Design
Scientists have uncovered the structural details of how some proteins interact to turn two different signals into a single integrated output.
New ACE-inhibiting Molecule Found in the Asparagus
Scientists have determined that sulfur-containing compounds in plants can inhibit ACE.
The Linking of Molecules and Microbes
Researchers have succeeded in making antibiotic substances and their bacterial producers simultaneously visible.
PTR-MS Breath Test Shows Potential for Detecting Liver Disease
Researchers at the University of Birmingham have published results that suggest a non-invasive breath test for liver disease using an IONICON PTR-MS.
New Test Could Distinguish Between Bipolar Disorder, Depression
Scientists are developing a test that could tell the difference between bipolar disorder and depression.
Early Detection of Lung Cancer
The University of Manchester has signed a collaboration agreement with Abcodia to perform proteomics studies on a cohort of non-small cell lung cancer cases from the UKCTOCS biobank, with the aim of discovering new blood-based biomarkers for earlier detection of the disease.
Detecting Hidden Ingredients
Researchers from China have used mass spectrometry to reveal the use of undeclared substances in dietary supplements.
How the Lung Repairs its Wounds
Researchers have gained detailed insights into the dynamic remodeling of the tissue during lung repair.
Automation Abound at AACC in Atlanta
Discover the latest breakthroughs, trends and products from the AACC Annual Meeting & Clinical Lab Expo.
Could a simple saliva test detect Alzheimer's?
Researchers have presented findings suggesting that a simple, non-invasive diagnostic for Alzheimer's could be within reach.
Scroll Up
Scroll Down
Skyscraper Banner

Skyscraper Banner
Go to LabTube
Go to eposters
 
Access to the latest scientific news
Exclusive articles
Upload and share your posters on ePosters
Latest presentations and webinars
View a library of 1,800+ scientific and medical posters
2,500+ scientific and medical posters
A library of 2,500+ scientific videos on LabTube
3,700+ scientific videos
Close
Premium CrownJOIN TECHNOLOGY NETWORKS PREMIUM FREE!