Corporate Banner
Satellite Banner
Spectroscopy
Scientific Community
 
Become a Member | Sign in
Home>News>This Article
  News
Return

Bruker Introduces Two New Analytical Accessories for Electron Microscopes

Published: Tuesday, August 06, 2013
Last Updated: Tuesday, August 06, 2013
Bookmark and Share
Company has introduced XSense™ and XTrace™ at the Microscopy & Microanalysis 2013 meeting.

At the Microscopy & Microanalysis 2013 Meeting, Bruker has introduced two new instruments which further expand its portfolio of high-performance tools for materials characterization in electron microscopes:

• XSense™ is a novel parallel beam wavelength dispersive X-ray spectrometer (WDS) for elemental analysis on scanning electron microscopes (SEM).

Specifically designed for the lower energy range between 100 and 3,600 eV, the XSense spectrometer provides energy resolution down to 4 eV, enabling both excellent separation of closely spaced X-ray lines and highly sensitive trace element detection.

• XTrace™ is a new micro-spot X-ray source that enables photon-induced micro X-ray fluorescence (micro-XRF) spectrometry on SEM systems, in conjunction with Bruker's energy dispersive X-ray spectrometer (EDS) detectors.

In comparison with electron-excited X-ray spectrometry commonly used for elemental analysis on SEMs, micro-XRF spectrometry provides 20 to 50 times lower limits of detection, in particular in the mid-to-high energy range of the spectrum, adding the capability of detecting and analyzing trace amounts of higher-Z elements in the sample.

The new XSense WDS analyzer uses special X-ray mirror optics for efficient large angle X-ray collection and parallelization. A fully motorized 3-axis auto-alignment system ensures fast, reproducible and stable positioning of the focal spot.

The parallel beam optics is fully retractable, and made of non-magnetic materials to avoid beam shift and image distortion. With a choice of six diffracting crystals, XSense can be tuned to provide optimum conditions for almost any application. Its advanced kinematics maintains optimum positioning of the active crystal with respect to the X-ray beam over the full scan range for maximum diffraction efficiency.

An additional, secondary X-ray optics between crystal and detector further enhances peak-to-background ratios and sensitivity of the XSense WDS. Bruker's unique detector management system actively controls the proportional counter's internal gas pressure and automatically performs all high voltage and discriminator settings.

When attached to an appropriate port of the SEM's sample chamber, the new XTrace is using a low-power micro-focus X-ray tube and focusing polycapillary X-ray optics to produce a highly intense X-ray beam for sample irradiation with spot sizes smaller than 40 microns.

Due to the alignment of the focal spot to hit the sample surface at the same position as the SEM's electron beam, the analyst can alternatively acquire both electron-induced and photon-induced X-ray fluorescence spectra from the same sample area.

While electron-induced X-ray spectroscopy provides high spatial resolution and excellent light element detection, photon excitation with XTrace is superior in sensitivity and allows trace element detection down to 10 ppm levels. Combining the information obtained with the two techniques can greatly enhance the accuracy of the analytical results.

Both the XSense WDS analyzer and the XTrace micro X-ray source are operated via ESPRIT 2.0, Bruker's new and unique 4-in-1 analytical software suite which seamlessly integrates EDS, WDS, EBSD and Micro-XRF under a single user interface.

ESPRIT 2.0 not only enables intuitive navigation within and between all four complementary methods, but also provides various possibilities for combining the data to obtain higher precision quantitative results.

Thomas Schülein, President of the Bruker Nano Analytics division, stated: "With the introduction of these exciting new products we are now offering our customers unprecedented options to significantly enhance the analytical power of their electron microscope. As integral parts of our QUANTAX system for micro- and nano-analysis, both new tools are designed to improve specificity and sensitivity of the analytical SEM over the full range of the energy spectrum. The XSense WDS is dedicated to the low energy, light element region, and the XTrace is particularly suited to reveal additional analytical information in the mid-to-high energy range. We are proud that Bruker is now the only vendor to offer all five techniques, EDS, WDS, EBSD, Micro-XRF and Micro-CT, as high-performance add-on analyzers for electron microscopes. Due to the full integration under our new ESPRIT 2.0 software suite, researchers can now combine and integrate data obtained by these complementary methods. As a result, our QUANTAX system has now evolved into a true multimodal analytical toolset for comprehensive materials characterization on electron microscopes."


Further Information

Join For Free

Access to this exclusive content is for Technology Networks Premium members only.

Join Technology Networks Premium for free access to:

  • Exclusive articles
  • Presentations from international conferences
  • Over 4,000+ scientific posters on ePosters
  • More than 5,300+ scientific videos on LabTube
  • 35 community eNewsletters


Sign In



Forgotten your details? Click Here
If you are not a member you can join here

*Please note: By logging into TechnologyNetworks.com you agree to accept the use of cookies. To find out more about the cookies we use and how to delete them, see our privacy policy.

Related Content

Bruker Reports First Quarter 2016 Financial Results
Bruker Corporation reported financial results for its first quarter ended March 31, 2016.
Wednesday, May 11, 2016
Bruker’s NMR FoodScreener™ Laboratory Achieves ISO/IEC 17025 Accreditation
Bruker announced that its NMR FoodScreener™ laboratory for food authenticity and quality determination, located in Rheinstetten, Germany, has been granted ISO/IEC 17025 accreditation.
Monday, September 28, 2015
World’s First Compact 900 MHz Actively Refrigerated Magnet for NMR Installed at UCSD
Bruker announce the successful installation of an Ascend™ Aeon 900 magnet, the world’s first compact, single-story NMR magnet with active refrigeration.
Wednesday, December 11, 2013
Novel Approach for Inborn Errors of Metabolism Screening by NMR
Clinical IEM-by-NMR screening study in Turkey measures 65 metabolites in urine simultaneously, including 20 endogeneous metabolites and 45 metabolites associated with inborn errors of metabolism.
Wednesday, September 04, 2013
Bruker Announces the Appointment of Thomas Bachmann
Appointment of Mr. Bachmann as President of the Bruker BioSpin Group.
Thursday, August 22, 2013
BEST Awarded Multiple Contracts Worth over $11 Million
BEST awarded contracts from Brookhaven National Lab and global beamline customers.
Friday, October 05, 2012
Bruker Announces New UK Centre of Excellence
Company introduces its integrated, state-of-the-art demonstration, applications and customer collaboration facilities.
Wednesday, October 03, 2012
Bruker Opens New Center of Excellence in Moscow
New Center for applications, technical sales, customer training and advanced service support.
Monday, June 18, 2012
Bruker and Berkeley Lab Collaborate on Novel Technology for Structural Biology
Berkeley Lab and Bruker intend to integrate SAXS and NMR data for 3D structure determination of multi-domain proteins and protein complexes with DNA, RNA or other proteins.
Thursday, November 24, 2011
Scientific News
Hunting the Missing Link Between Genetics and the Environment
The International Phenome Centre Network (IPCN) works to transform healthcare through phenomics - the dynamic interactions between our genes and our environment.
Chemical Snapshots Could Lead to Better Engineered Cartilage
Taking "chemical photographs" of the cartilage between joints and comparing it to engineered versions could lead to better implants, say researchers.
Identifying Functional Biomarkers of Traumatic Brain Injury
In this study, prefrontal hemodynamic biomarkers were identified that can distinguish traumatic brain injury patients from healthy subjects.
Peer Review is in Crisis, But Should be Fixed, Not Abolished
After the time to get the science done, peer review has become the slowest step in the process of sharing studies, and some scientists have had enough.
Identification of Individual Red Blood Cells by Raman Microspectroscopy
In this study, Raman Microspectroscopy was used to identify individual red blood cells.
The Power Of Orthogonality In Assessing The Stability Of Biopharmaceuticals
By utilizing orthogonal techniques, researchers can maximize the secure application of all analytical results generated.
3D-Printing in Science: Conference Co-Staged with LABVOLUTION
LABVOLUTION 2017 will have an added highlight of a simultaneous conference, "3D-Printing in Science".
Curcumin Shows Promise as Cancer Treatment
When delivered at the correct circadian phase, curcumin demonstrates sustained toxicity in cancer cells and should be considered for use in patient care.
Using the Linkam THMS600 Temperature Stage to Study Fluid Inclusions
The University of Lyon use the Linkam THMS600 temperature stage for the study of Brillouin spectroscopy of fluid inclusions.
Guided Needles Hit the Mark
New sensor could help anesthesiologists place needles for epidurals and other medical procedures.
Skyscraper Banner

SELECTBIO Market Reports
Go to LabTube
Go to eposters
 
Access to the latest scientific news
Exclusive articles
Upload and share your posters on ePosters
Latest presentations and webinars
View a library of 1,800+ scientific and medical posters
4,000+ scientific and medical posters
A library of 2,500+ scientific videos on LabTube
5,300+ scientific videos
Close
Premium CrownJOIN TECHNOLOGY NETWORKS PREMIUM FOR FREE!