Axon Axopatch 200B Capacitor Feedback Patch Clamp Amplifier

Product Description
Widely accepted as the gold-standard for ultra low-noise patch clamp recordings, the Axopatch™ 200B Capacitor Feedback Patch Clamp Amplifier is the benchmark for single-channel recordings and other applications that require an excellent signal-to-noise ratio. By introducing active cooling of components in the headstage to well below 0°C, the open-circuit noise in patch mode has been reduced to unprecedented levels, as low as <15 fA (RMS) at 0.1 - 1 kHz. This translates into significantly lower noise during patch clamp recordings. A headstage that can be switched to resistive mode ensures superb performance in whole-cell recordings, too. This makes the Axopatch 200B System the amplifier of choice for a scientist who performs basic research in the ion channel field and is the reason why researchers purchased thousands of these amplifiers from Molecular Devices over the past decade.

In addition to ultra-low noise and whole-cell performance, the slim design of the headstage improves electrode access to the preparation by making it easier to fit under your microscope. The Axopatch 200B Amplifier gives you the utmost flexibility through three recording configurations in a single headstage: one patch and two whole cell ranges, with capacitance compensation ranges of 100 pF and 1000 pF. Increased voltage and current command ranges (up to ±1V) are useful for electrochemical measurements. The built-in capacitance dithering capability enables highly accurate capacitance measurements. Seal test has become more versatile, featuring current steps in current clamp mode as well as voltage steps in voltage clamp mode. The recording bandwidth has been extended up to 100 kHz, allowing you to capture even the fastest events. Series resistance compensation is active in current clamp as well as in voltage clamp mode to enable bridge balance operation and improve amplifier performance.
Product Axon Axopatch 200B Capacitor Feedback Patch Clamp Amplifier
Company Molecular Devices Product Directory
Price Request a quote
More Information View company product page
Catalog Number Unspecified
Quantity Unspecified
Company Logo

Molecular Devices Product Directory
1311 Orleans Drive Sunnyvale, CA 94089-11361 United States

Tel: 1-800-635-5577
Fax: 1-408-548-6439

Scientific News
Integrated Omics Analysis
Studying multi-omics promises to give a more holistic picture of the organism and its place in its ecosystem, however despite the complexities involved those within the field are optimistic.
Unravelling the Role of Key Genes and DNA Methylation in Blood Cell Malignancies
Researchers from the University of Nebraska Medical Center have demonstrated the role of Dnmt3a in safeguarding normal haematopoiesis.
Salford Lung Study - The First Real World Clinical Trial
In this podcast, we learn about the Salford Lung Study and its potential to revolutionize the way we assess new drugs and treatments around the world.
Point of Care Diagnostics - A Cautious Revolution
Advances in molecular biology, coupled with the miniaturization and improved sensitivity of assays and devices in general, have enabled a new wave of point-of-care (POC) or “bedside” diagnostics.
Structure of Primary Cannabinoid Receptor is Revealed
The findings provide key insights into how natural and synthetic cannabinoids including tetrahydrocannabinol —a primary chemical in marijuana—bind at the CB1 receptor to produce their effects.
Overlooked Molecules Could Revolutionise our Understanding of the Immune System
Researchers have discovered that around one third of all the epitopes displayed for scanning by the immune system are a type known as ‘spliced’ epitopes.
Illumina Contributes to ClinVar Database
The contribution includes variants of all classifications, from pathogenic to benign, identified during interpretation of whole genome sequences generated in the CLIA-certified, CAP-accredited Illumina Clinical Services Laboratory.
Agilent Presents Early Career Professor Award to Dr. Roeland Verhaak
JAX professor recognized for the development and implementation of workflows for the analysis of big-data from transcriptomics to next generation sequencing approaches.
NIH Study Determines Key Differences between Allergic and Non-Allergic Dust Mite Proteins
Researchers at NIH have uncovered factors that lead to the development of dust mite allergy and assist in the design of better allergy therapies.
NIH Contributes to Global Effort to Prevent and Manage Lung Diseases
The large scale trial will measure health benefits of clean cookstoves.
Scroll Up
Scroll Down

Skyscraper Banner

Skyscraper Banner
Go to LabTube
Go to eposters
Access to the latest scientific news
Exclusive articles
Upload and share your posters on ePosters
Latest presentations and webinars
View a library of 1,800+ scientific and medical posters
3,500+ scientific and medical posters
A library of 2,500+ scientific videos on LabTube
5,100+ scientific videos