Atlas Potassium Pressure System

Product Description

atlas_potassium_pressure_system copy.gif



The Atlas Potassium Pressure System is a modular 3 bar pressure reactor that can be controlled automatically or manually. Available in volumes from 100ml to 3 litres the Atlas Potassium Pressure System offers heating and/or cooling, overhead stirring, pressure sensing and options such as pressure control, mass flow control, gas selection automated addition and reaction sampling.

Designed specifically for applications such as hydrogenations or carbonylations where elevated pressures are required. Syrris currently offer two types of pressure vessel: Atlas Sodium Pressure System and Atlas Potassium Pressure System. Both systems are modular and are available with or without full automation.

The Potassium Pressure System is part of Atlas from Syrris, a revolutionary range of modular products, which can form a wide range of lab reactors - designed specifically for research and development chemists. Atlas offers manual or automated control of one or many reactions at a time with volumes from 5 litres to 1ml in jacketed reactors, flasks or vials.

Features & Benefits

Quick change vessel: The oil drain unit, jacketed vessel clamp and quick oil connectors allow vessels to be changed in under a minute.

Easy to use: No tools required, twist and click control knob, large display and intuitive.

High performance stirring: The Atlas Sodium Pressure System offers powerful overhead stirring.

3 bar pressure: The Atlas Potassium Pressure System has an operating pressure of up to 3 bar (see the Custom Reactor Systems for higher pressure).

Variety of vessels: The Atlas Potassium Pressure System can be supplied with 100ml, 250ml, 500ml, 1L, 2L or 3L glass reaction vessels with or without vacuum jacket.

Safe: Burst disc, pressure relief valve and complies with PED / ASME design codes.

Automation and data-logging without PC: Automatic profiles are possible for reaction temperature, stirrer speed, reagent addition and sampling. All data is logged in a .csv file and can be downloaded to a USB stick automatically.

Optional PC control: The PC software offers advanced recipe control, total automation of all parameters, alarms and real time graphs.

Wide temperature range: -80 to +200°C.

Product Atlas Potassium Pressure System
Company Syrris Ltd - Product Directory
Price Request a quote
More Information View company product page
Catalog Number Unspecified
Quantity Unspecified
Company Logo

Syrris Ltd - Product Directory
Unit 1, Anglian Business Park Orchard Road, Royston Herts SG8 5TW United Kingdom

Tel: +44 (0) 1763 242555
Fax: +44 (0) 1763 242 992
Email: info@syrris.com



Scientific News
The Changing Tides of the In Vitro Diagnostics Market
With the increasing focus in personalized medicine, diagnostics plays a crucial role in patient monitoring.
LaVision BioTec Reports on the Neuro Research on the Human Brain After Trauma
Company reports on the work of Dr Ali Ertürk from the Institute for Stroke and Dementia Research at LMU Munich.
NIH Study Shows No Benefit of Omega-3 Supplements for Cognitive Decline
Research was published in the Journal of the American Medical Association.
Less May Be More in Slowing Cholera Epidemics
Mathematical model shows more cases may be prevented and more lives saved when using one dose of cholera vaccine instead of recommended two doses.
Investigating the Vape
Expert independent review concludes that e-cigarettes have potential to help smokers quit.
NIH Launches Human RSV Study
Study aims to understand infection in healthy adults to aid development of RSV medicines, vaccines.
Researchers Discover Synthesis of a New Nanomaterial
Interdisciplinary team creates biocomposite for first time using physiological conditions.
Poor Survival Rates in Leukemia Linked to Persistent Genetic Mutations
For patients with an often-deadly form of leukemia, new research suggests that lingering cancer-related mutations – detected after initial treatment with chemotherapy – are associated with an increased risk of relapse and poor survival.
Flu Remedies Help Combat E. coli Bacteria
Physiologists from the University of Zurich have now discovered why the intestinal bacterium Escherichia coli (E. coli) multiplies heavily and has an inflammatory effect.
Marijuana Genome Unraveled
A study by Canadian researchers is providing a clearer picture of the evolutionary history and genetic organization of cannabis, a step that could have agricultural, medical and legal implications for this valuable crop.
Scroll Up
Scroll Down

Skyscraper Banner

Skyscraper Banner
Go to LabTube
Go to eposters
 
Access to the latest scientific news
Exclusive articles
Upload and share your posters on ePosters
Latest presentations and webinars
View a library of 1,800+ scientific and medical posters
2,500+ scientific and medical posters
A library of 2,500+ scientific videos on LabTube
3,700+ scientific videos
Close
Premium CrownJOIN TECHNOLOGY NETWORKS PREMIUM FREE!