HU15 Standard - Setting the standard for horizontal gel electrophoresis

Product Description
Scie-Plas™ Green Range™ horizontal gel electrophoresis units offer the ultimate standards in innovative design and manufacture, acquired during our 20-year existence. The Scie-Plas Green Range horizontal gel electrophoresis units currently comprise models with gel tray sizes ranging from 6 x 7.5 to 25 x 30cm. All models incorporate many design and safety features recommended by scientists, either from within our in-house product development team or laboratories worldwide. As a result, all our models are manufactured and finished to the highest specification, easy to use, and, with safety always paramount, CE-marked - conforming to European safety regulations.

The HU15 Standard horizontal gel unit provides the sample throughput and tray-size options most popular in today's market, but includes additional casting options. A maximum 120-sample throughput makes this unit a highly versatile option for screening samples ranging from DNA mini-preps to PCR products. Each unit is supplied with a UV-transparent 15 x 15cm gel tray whose four comb slots are positioned in regular 3.5cm intervals to reduce sample migration time. Buffer recirculation ports are provided as standard so that the HU15 may be connected to the Watson Marlow buffer recirculation pump, which is also available through Scie-Plas.

Casting gates with integral silicone seals ensure effective leak-free casting, while HU15-SS Scie-Plas Super-Seals can be positioned anywhere within the gel tray to afford the user complete flexibility in gel length selection.


Complete System
Standard horizontal gel unit with removable casting tray, including casting gates with integral silicone seals, 2 x 1mm thick, 16-sample combs, coloured loading strips and buffer recirculation ports
Unit Dimensions (W x L x H): 21.5 x 33.5 x 7cm
Gel Size (W x L): 15 x 15cm
Buffer Volume: 1200ml
Maximum Sample Capacity: 120
Recommended Power Supplies: Consort EV222 & EV243
Product HU15 Standard - Setting the standard for horizontal gel electrophoresis
Company Scie-Plas Ltd
Price Request a quote
More Information View company product page
Catalog Number Unspecified
Quantity 1
Company Logo

Scie-Plas Ltd
22 Cambridge Science Park Milton Road Cambridge CB4 0FJ UK

Tel: +44 (0) 1223 427888
Fax: +44 (0) 1223 420164

Scientific News
Integrated Omics Analysis
Studying multi-omics promises to give a more holistic picture of the organism and its place in its ecosystem, however despite the complexities involved those within the field are optimistic.
Unravelling the Role of Key Genes and DNA Methylation in Blood Cell Malignancies
Researchers from the University of Nebraska Medical Center have demonstrated the role of Dnmt3a in safeguarding normal haematopoiesis.
Salford Lung Study - The First Real World Clinical Trial
In this podcast, we learn about the Salford Lung Study and its potential to revolutionize the way we assess new drugs and treatments around the world.
Point of Care Diagnostics - A Cautious Revolution
Advances in molecular biology, coupled with the miniaturization and improved sensitivity of assays and devices in general, have enabled a new wave of point-of-care (POC) or “bedside” diagnostics.
Mass Spec Technology Drives Innovation Across the Biopharma Workflow
With greater resolving power, analytical speed, and accuracy, new mass spectrometry technology and techniques are infiltrating the biopharmaceuticals workflow.
Structure of Primary Cannabinoid Receptor is Revealed
The findings provide key insights into how natural and synthetic cannabinoids including tetrahydrocannabinol —a primary chemical in marijuana—bind at the CB1 receptor to produce their effects.
Overlooked Molecules Could Revolutionise our Understanding of the Immune System
Researchers have discovered that around one third of all the epitopes displayed for scanning by the immune system are a type known as ‘spliced’ epitopes.
Illumina Contributes to ClinVar Database
The contribution includes variants of all classifications, from pathogenic to benign, identified during interpretation of whole genome sequences generated in the CLIA-certified, CAP-accredited Illumina Clinical Services Laboratory.
Agilent Presents Early Career Professor Award to Dr. Roeland Verhaak
JAX professor recognized for the development and implementation of workflows for the analysis of big-data from transcriptomics to next generation sequencing approaches.
NIH Study Determines Key Differences between Allergic and Non-Allergic Dust Mite Proteins
Researchers at NIH have uncovered factors that lead to the development of dust mite allergy and assist in the design of better allergy therapies.
Scroll Up
Scroll Down

Skyscraper Banner

Skyscraper Banner
Go to LabTube
Go to eposters
Access to the latest scientific news
Exclusive articles
Upload and share your posters on ePosters
Latest presentations and webinars
View a library of 1,800+ scientific and medical posters
3,500+ scientific and medical posters
A library of 2,500+ scientific videos on LabTube
5,100+ scientific videos