Satellite Banner
Scientific Communities
Become a Member | Sign in
Home>Products>This Product

HU6 Mini - The 6cm wide mini horizontal

Product Description
Scie-Plas™ Green Range™ horizontal gel electrophoresis units offer the ultimate standards in innovative design and manufacture, acquired during our 20-year existence. The Scie-Plas Green Range horizontal gel electrophoresis units currently comprise models with gel tray sizes ranging from 6 x 7.5 to 25 x 30cm. All models incorporate many design and safety features recommended by scientists, either from within our in-house product development team or laboratories worldwide. As a result, all our models are manufactured and finished to the highest specification, easy to use, and, with safety always paramount, CE-marked - conforming to European safety regulations.

The HU6 Mini horizontal gel unit is ideal for routine preparatory and analytical electrophoresis techniques. It has a maximum 32-sample throughput capacity and features a removable gel-casting tray with end gaskets that allow gels to be cast directly within the tank. The gel-casting tray is simply turned at 90° to the direction of electrophoresis, when the end gaskets form a leak proof seal against the inner walls of the running chamber. Once the gel has set and is ready for loading, the gel-casting tray is then restored to its correct orientation in the direction of electrophoresis.

Alternatively, single gels may be cast outside of the tank using HU6-SCG silicone casting gates or HU6-SS Scie-Plas Super-Seals, while up to 3 additional gels may be cast simultaneously within the HU6-CU mini-gel external casting unit.


Complete System
Mini horizontal gel unit with removable casting tray and 2 x 1mm thick, 8-sample combs and coloured loading strips
Unit Dimensions (W x L x H): 13 x 24 x 6.5cm
Gel Dimensions (W x L): 6 x 7.5cm
Buffer Volume: 325ml
Maximum Sample Capacity: 32
Recommended Power Supplies: Consort EV222
Product HU6 Mini - The 6cm wide mini horizontal
Company Scie-Plas Ltd
Price Request a quote
More Information View company product page
Catalog Number Unspecified
Quantity 1
Company Logo

Scie-Plas Ltd
22 Cambridge Science Park Milton Road Cambridge CB4 0FJ UK

Tel: +44 (0) 1223 427888
Fax: +44 (0) 1223 420164

Scientific News
Integrated Omics Analysis
Studying multi-omics promises to give a more holistic picture of the organism and its place in its ecosystem, however despite the complexities involved those within the field are optimistic.
Unravelling the Role of Key Genes and DNA Methylation in Blood Cell Malignancies
Researchers from the University of Nebraska Medical Center have demonstrated the role of Dnmt3a in safeguarding normal haematopoiesis.
Salford Lung Study - The First Real World Clinical Trial
In this podcast, we learn about the Salford Lung Study and its potential to revolutionize the way we assess new drugs and treatments around the world.
Point of Care Diagnostics - A Cautious Revolution
Advances in molecular biology, coupled with the miniaturization and improved sensitivity of assays and devices in general, have enabled a new wave of point-of-care (POC) or “bedside” diagnostics.
Mass Spec Technology Drives Innovation Across the Biopharma Workflow
With greater resolving power, analytical speed, and accuracy, new mass spectrometry technology and techniques are infiltrating the biopharmaceuticals workflow.
Structure of Primary Cannabinoid Receptor is Revealed
The findings provide key insights into how natural and synthetic cannabinoids including tetrahydrocannabinol —a primary chemical in marijuana—bind at the CB1 receptor to produce their effects.
Overlooked Molecules Could Revolutionise our Understanding of the Immune System
Researchers have discovered that around one third of all the epitopes displayed for scanning by the immune system are a type known as ‘spliced’ epitopes.
Illumina Contributes to ClinVar Database
The contribution includes variants of all classifications, from pathogenic to benign, identified during interpretation of whole genome sequences generated in the CLIA-certified, CAP-accredited Illumina Clinical Services Laboratory.
Agilent Presents Early Career Professor Award to Dr. Roeland Verhaak
JAX professor recognized for the development and implementation of workflows for the analysis of big-data from transcriptomics to next generation sequencing approaches.
NIH Study Determines Key Differences between Allergic and Non-Allergic Dust Mite Proteins
Researchers at NIH have uncovered factors that lead to the development of dust mite allergy and assist in the design of better allergy therapies.
Scroll Up
Scroll Down

Skyscraper Banner

Skyscraper Banner
Go to LabTube
Go to eposters
Access to the latest scientific news
Exclusive articles
Upload and share your posters on ePosters
Latest presentations and webinars
View a library of 1,800+ scientific and medical posters
3,500+ scientific and medical posters
A library of 2,500+ scientific videos on LabTube
5,100+ scientific videos