Corporate Banner
Satellite Banner
Technology
Networks
Scientific Communities
 
Become a Member | Sign in
Home>Products>This Product
  Products


LUMIstar Omega Luminescence Microplate Reader

Product Description
lumistar-omega.jpg

The LUMIstar OMEGA is a compact, modular luminescence microplate reader that is designed for the widest possible range of applications based on luminescence detection such as luciferases, Renilla, DLR, and aequorin.

The LUMIstar Omega is a highly sensitive luminescence microplate reader for flash and glow luminescence assays including:

• Luciferase reporter gene assays, promoter analysis
• Luminescent immunoassays
• Cell-based assays and viability
• Intracellular Ca2+ with aequorin
• Ion channel, GPCR screening
• ATP assays
• GUS assays (ß-glucuronidase)
• ROS (reactive oxygen species)
• BRET assay for monitoring intermolecular interactions
• Enzyme activity assays (e.g. evaluation of PARP inhibitors, screen for cytochrome P450 inhibitors, protein kinase assay)
• Nucleic acid detection (PCR quantification)

Additional features
Through onboard reagent injectors the LUMIstar Omega offers point of measurement injection for initiating fast kinetic events. Other outstanding features include a built-in filter wheel for color discrimination assays, shaking, incubation up to 45°C or even 65°C and much more. Simultaneous Dual Emission detection is also available for BRET applications.

Gas Control Capabilities
Using a proprietary Atmospheric Control Unit (ACU), the LUMIstar Omega independently controls both the O2 (1-19%) and CO2 (0-20%) gas concentrations within the microplate reader chamber.
Upgradeable to multimode microplate reader with spectrometer
The LUMIstar Omega microplate luminometer can be upgraded to include fluorescence intensity and time-resolved fluorescence measurement capabilities (the FLUOstar Omega multimode microplate reader). The LUMIstar Omega can also be upgraded to include fluorescence polarization (POLARstar Omega) as well as ultra-fast, full spectrum absorbance (SPECTROstar Omega).

Stacker and robot compatibility
For medium level throughput, the LUMIstar Omega can be equipped with a 50 plate Stacker with optional bar code reader. For even higher throughput, the LUMIstar Omega can be integrated into all existing robotic systems via DDE or ActiveX interface.

Software package
The LUMIstar Omega license-free software includes the Omega Reader Control and the MARS Data Analysis software. This highly intuitive software provides limitless possibilities for test set-up and data analysis, while also offering one-click, app-style application shortcuts for running routine tests and data analyses. One click calculations include percent CVs, standard deviations, Z' value, Lineweaver-Burk plots, IC-50/EC-50, DNA quantitation, and enzyme kinetic calculations including Michaelis-Menten
Product LUMIstar Omega Luminescence Microplate Reader
Company BMG Labtech GmbH
Price Request a quote
More Information View company product page
Catalog Number Unspecified
Quantity Unspecified
Company Logo

BMG Labtech GmbH
Allmendgruen 8, 77799 Ortenberg Germany

Tel: +49 781 96968-0
Fax: +49 781 96968-67
Email: hts@bmglabtech.com



Scientific News
The Changing Tides of the In Vitro Diagnostics Market
With the increasing focus in personalized medicine, diagnostics plays a crucial role in patient monitoring.
LaVision BioTec Reports on the Neuro Research on the Human Brain After Trauma
Company reports on the work of Dr Ali Ertürk from the Institute for Stroke and Dementia Research at LMU Munich.
NIH Study Shows No Benefit of Omega-3 Supplements for Cognitive Decline
Research was published in the Journal of the American Medical Association.
Less May Be More in Slowing Cholera Epidemics
Mathematical model shows more cases may be prevented and more lives saved when using one dose of cholera vaccine instead of recommended two doses.
Investigating the Vape
Expert independent review concludes that e-cigarettes have potential to help smokers quit.
NIH Launches Human RSV Study
Study aims to understand infection in healthy adults to aid development of RSV medicines, vaccines.
Researchers Discover Synthesis of a New Nanomaterial
Interdisciplinary team creates biocomposite for first time using physiological conditions.
Poor Survival Rates in Leukemia Linked to Persistent Genetic Mutations
For patients with an often-deadly form of leukemia, new research suggests that lingering cancer-related mutations – detected after initial treatment with chemotherapy – are associated with an increased risk of relapse and poor survival.
Flu Remedies Help Combat E. coli Bacteria
Physiologists from the University of Zurich have now discovered why the intestinal bacterium Escherichia coli (E. coli) multiplies heavily and has an inflammatory effect.
Marijuana Genome Unraveled
A study by Canadian researchers is providing a clearer picture of the evolutionary history and genetic organization of cannabis, a step that could have agricultural, medical and legal implications for this valuable crop.
Scroll Up
Scroll Down

Skyscraper Banner

Skyscraper Banner
Go to LabTube
Go to eposters
 
Access to the latest scientific news
Exclusive articles
Upload and share your posters on ePosters
Latest presentations and webinars
View a library of 1,800+ scientific and medical posters
2,500+ scientific and medical posters
A library of 2,500+ scientific videos on LabTube
3,700+ scientific videos
Close
Premium CrownJOIN TECHNOLOGY NETWORKS PREMIUM FREE!