We've updated our Privacy Policy to make it clearer how we use your personal data.

We use cookies to provide you with a better experience. You can read our Cookie Policy here.

Advertisement
Development of a Screening Method for the Determination of PCBs in Water
News

Development of a Screening Method for the Determination of PCBs in Water

Development of a Screening Method for the Determination of PCBs in Water
News

Development of a Screening Method for the Determination of PCBs in Water

Read time:
 

Want a FREE PDF version of This News Story?

Complete the form below and we will email you a PDF version of "Development of a Screening Method for the Determination of PCBs in Water"

First Name*
Last Name*
Email Address*
Country*
Company Type*
Job Function*
Would you like to receive further email communication from Technology Networks?

Technology Networks Ltd. needs the contact information you provide to us to contact you about our products and services. You may unsubscribe from these communications at any time. For information on how to unsubscribe, as well as our privacy practices and commitment to protecting your privacy, check out our Privacy Policy

Abstract
A new method has been developed and validated for the simultaneous analysis of 11 polychlorinated biphenyls (PCBs), in water samples at trace levels by gas chromatography coupled to triple quadrupole mass spectrometry (GC-QqQ-MS/MS). Water samples were extracted by the QuEChERS (Quick Easy Cheap Effective Rugged and Safe) method. The QqQ analyzer acquired data in multiple reactions monitoring (MRM), permitting both quantification and confirmation in a single injection with a running time reduced up to 11.0 min. The effect of matrix interferences in extracts on analyte quantification and the identification of PCBs in water samples was deeply studied. The results showed that PCBs were prone to strong matrix interactions in water samples, and the quantification and identification of PCBs were highly affected by a matrix enhancement effect. To evaluate the performance of the method, validation experiments were carried out on water samples at three spiking levels (1.6, 8.0, 40.0 µg L(-1)). Recovery was in the range of 95 - 109% at 1.6 µg L(-1), 90 - 95% at 8.0 µg L(-1) and 97 - 102% at 40.0 µg L(-1), respectively. Precision values expressed as relative standard deviation (RSD) were lower than 15%. Linearity in the range of 0.5 - 50.0 µg L(-1) provided determination coefficients (R(2)) higher than 0.999 for all compounds. The limits of detection (LODs) for PCBs were ≤0.1 µg L(-1) and the limits of quantification (LOQs) ranged from 0.04 to 0.3 µg L(-1). The applicability of the proposed method to detect and quantify PCBs has been demonstrated in analyse of 15 real samples.

The article is published online in the journal Analytical Sciences and is free to access.

Advertisement