Lubricant, Olive Oil, Motor Oil - Test viscous liquids with the Specac Pearl

Listen with
Speechify
0:00
Register for free to listen to this article
Thank you. Listen to this article using the player above.

Want to listen to this article for FREE?

Complete the form below to unlock access to ALL audio articles.

Read time: 1 minute

The Pearl houses all fluid consistencies, no mess and no fuss. With a pipette or with a syringe, users can introduce a liquid sample and clean up in seconds. 

Today we’re specifically looking at the testing of viscous liquids such as oils and greases. This brief application note will go through The Pearl’s following processes and benefits:

1. Introduce sample (quickly)

2. Test sample (accurately)

3. Clean Pearl (easily)

We’ve included a sample result for your delectation, after setting out the testing process.

Introduction

Find a viscous liquid to sample. Don’t spill it.

Pull out The Pearl’s sample draw and open the Oyster Cell by lifting-and-tilting its upper window. 

 pearlvid5.JPG

With a pipette, introduce a small amount of the sample onto the lower window of the Oyster Cell. 

When you close the Oyster Cell, the liquid cavity is sealed between the top and bottom windows. 

Close and check through the top window for any bubbles or other visible sample imperfections. 

 

If you’re happy, close the sliding draw and prepare to test. Done.

Testing

The lower window in the Oyster Cell is interchangeable. 

Changing this lower window allows you to choose an optimum pathlength and whether you’d like the two windows parallel to each other or at a wedged angle. 

pearlvid4.JPG

A wedged angle guarantees no fringing pattern when you measure an empty cell.

In our example, we tested cooking oils. 

We used a Shimadzu IR Affinity spectrometer to collect data. 16 scans were obtained at 4m-1 resolution, using the DTGS detector for all samples run. 

We fitted the appropriate 50 micron or 100 micron pathlength wedged Oyster Cell, then tested the empty Oyster Cell to collect a reference background spectrum

We changed the lower Oyster Cell window twice to adjust pathlength. Window assembly P/N GS33221 for 50 micron, P/N GS33222 for 100 micron.

Cleaning

Collect your spectral reading. Open the sliding tray. Open the hinged Oyster Cell by lifting-and-tilting the top window. Wipe the Oyster Cell windows clean.

pearlvid9.JPG

Use a soft lens cleaning-type tissue, moistened with a suitable solvent if needed. Then wipe with a dry lens cleaning-type tissue. Now you’re ready for your next sample. 

If only all cleaning was this easy. Get in touch for more info.

Final word

Most people dread setting up and cleaning up, but we’ve reduced those steps to moments. Just don’t spill oil on the floor, because The Pearl can’t fix that and it’s very slippy.

Here’s a snippet of our top secret cooking oil data collected with The Pearl.

Picture1.png

 Olive Oil in a 50 microns pathlength wedged ZnSe Oyster Cell

 Picture2.png

Corn Oil in a 50 microns pathlength wedged ZnSe Oyster Cell