We've updated our Privacy Policy to make it clearer how we use your personal data. We use cookies to provide you with a better experience. You can read our Cookie Policy here.

Advertisement

Quadrupole Mass Spectrometers for UHV/XHV Studies

Listen with
Speechify
0:00
Register for free to listen to this article
Thank you. Listen to this article using the player above.

Want to listen to this article for FREE?

Complete the form below to unlock access to ALL audio articles.

Read time: Less than a minute
Hiden Analytical introduce a family of quadrupole mass spectrometers designed specifically for UHV/XHV performance, evolved from the Hiden 3F-series concept and incorporating the triple-stage mass filter technology for optimum mass separation, ion transmission efficiency and contamination resistance.

Pulse ion counting detection is common throughout this series for highest sensitivity and response times, with choice of positive-ion-only or combined positive and negative ion detection.

Quadrupole mean energy scanning is featured for systems configured for analysis of externally generated ions, enabling ion energy distribution measurement and optimization for neutrals analysis.

All systems feature the Windows-MASsoft Pro multi-mode control program with multi-parameter scanning for optimization of operating parameters for each individual mass channel. Ion detection is by fast pulse counting with continuous 7-decade scaling from 1c/s to 10E+7c/s. Sampling rates exceed 500 measurements per second, with partial pressure detection down to 5x10E-15 mbar and trace level detection to 5ppb.

A choice of ionization sources enables system optimization for varied applications including molecular beam, laser ablation, thermal desorption and general neutrals studies. All ion source parameters are software controlled with modes for ion attachment, ‘soft’ ionization and appearance potential measurement.