We've updated our Privacy Policy to make it clearer how we use your personal data. We use cookies to provide you with a better experience. You can read our Cookie Policy here.

Advertisement

Request Information

To request more information about this product, please complete the form below.

SCIEX ZenoTOF 8600 mass spectrometer with a sleek silver and blue design is shown against a soft gradient background.
Credit: Sciex
Request Information
Product
Advertisement

The ZenoTOF 8600: The Proof Is in the Data

The ZenoTOF 8600: The Proof Is in the Data
Credit: Sciex

To drive new discoveries and prove biological significance, you need technology that can outperform what you currently have. You need technology that unlocks new approaches that weren’t possible before. You need quantitative data of the highest quality; data you can stake your reputation on. 


The SCIEX ZenoTOF 8600 system combines proven technology from our most sensitive triple quad with our most versatile Zeno trap-enabled QTOF. Delivering 10x better sensitivity than the current SCIEX accurate mass system across many new and established accurate mass approaches. This translates not only into the lower limits of quantitation but also into new enabled approaches to making biologically relevant discoveries that data can prove. 


In the quest to make groundbreaking biological discoveries, the quality of data and the technology used are paramount. The ZenoTOF 8600 system represents a leap forward in mass spectrometry, offering noteworthy sensitivity and precision. You’re understandably skeptical. You’re supposed to be. That’s why we’re giving you access to the technical data driving our claims as a part of our launch, so you can see for yourself.


View the ZenoTOF 8600 system


Product Specifications
Sensitivity Zeno MS/MS (positive ESI) Reserpine 50 fg on column using the fragment m/z 195.0651,with a 10 mDa MEW S/N > 8000
Sensitivity Zeno MS/MS (negative ESI) Chloramphenicol 100 fg on column using the fragment m/z 152.0350,with a 10 mDa MEW S/N > 15000
MS/MS duty cycle When activated, the Zeno trap allows ≥90% duty cycle for TOF MS/MS acquisition
Fragmentation modes Collision induced dissociation (CID) and electron activated dissociation (EAD)
Mass resolution, positive ESI ≥ 45,000 (FWHM) measured on the [M+6H]6+ chargeisotope cluster for bovine insulin at m/z 956
Mass accuracy MS/MS, internal ≤0.2 ppm absolute error as demonstrated on m/z 813 fragment ionof Glu-Fibrinopeptide B, internally calibrated ≤0.5 ppm absolute error as demonstrated on m/z 120 fragment ion of Glu-Fibrinopeptide B, internally calibrated
Mass range TOF: up to 40 kDa, Precursor ion selection: m/z 5-2250
Detector type A long-life, wide dynamic range optical-based pulse counting, 4-channel detector, utilizing ADC signal capture technology
Intra-scan dynamic range In both TOF MS and Zeno MS/MS; ≥ 5 orders of magnitude linear dynamic range without signal reduction for Atorvastatin
Linear dynamic range negative In both TOF MS and Zeno MS/MS; ≥ 5 orders of magnitude linear dynamic range without signal reduction for Chloramphenicol
About SCIEX
SCIEX empowers customers to solve the most impactful analytical challenges in quantitation and characterization. For over 50 years, SCIEX has been at the forefront of the field with groundbreaking innovation, reliability, and support. Since the launch of the first-ever commercially successful triple quadrupole in 1981, their technologies and solutions have influenced life-changing research and outcomes. Thousands of life science experts worldwide rely on SCIEX to get the answers they can trust.
Interested in seeing more content from SCIEX?
Discover all their latest news, webinars, products and more by clicking the link below.