TruQuant: Verified Metabolite Identification and Error Correction for Reproducible Metabolomics
Reliable metabolomics starts with confident compound identification and consistent measurement. Differences in sample composition, ion suppression, and analytical performance can obscure biological changes and undermine comparisons across samples and batches. The TruQuant Yeast Extract Semi-Targeted QC Workflow Kit from IROA Technologies combines uniquely carbon-13-labeled standards with ClusterFinder™ software to help researchers identify metabolites, correct measurement variability, and generate more reproducible LC-MS metabolomics data.
Two complementary standards. One integrated workflow.
TruQuant combines a complex Internal Standard (IROA-IS) with a Long-Term Reference Standard (IROA-LTRS). Both are derived from isotopically labeled yeast extracts containing a broad range (600-1000) of metabolites.
The IROA-IS is added to experimental samples, providing labeled counterparts for metabolites represented in the sample. Its distinctive isotope patterns allow ClusterFinder to distinguish internal-standard signals and locate corresponding natural-abundance sample signals to enable metabolite identification and measurement.The IROA-LTRS is analyzed separately to establish a reference dictionary under the laboratory’s own chromatographic and mass spectrometric conditions. This dictionary captures retention times, mass-to-charge ratios, and associated compound characteristics. Periodic reference-standard injections support monitoring of analytical performance throughout a run and across batches.
Correct ion suppression before normalizing results.
Sample-dependent ion suppression can change a metabolite’s measured signal without a corresponding change in its concentration. TruQuant uses the response of the corresponding labeled internal standard to assess and correct this effect for metabolites with suitable internal-standard counterparts.
ClusterFinder then applies Dual MSTUS normalization, using artifact-filtered metabolite signals and their corresponding internal-standard signals to improve comparability among samples. Addressing ion suppression and sample-to-sample variation as distinct steps helps researchers interpret biological differences with greater confidence.
Turn complex LC-MS data into useful results.
ClusterFinder brings the standards and analytical data together in an integrated analysis workflow.
Its capabilities include:
• Recognition of characteristic IROA isotope patterns.
• Reference dictionary construction and metabolite identification.
• Artifact recognition and association of related peak signals.
• Metabolite-specific ion suppression correction.
• Dual MSTUS normalization.
• Reporting of raw, suppression-corrected, and normalized measurements.
Build confidence in biological interpretation.
For laboratories conducting biomarker discovery, metabolic profiling, or studies spanning multiple analytical batches, TruQuant provides a consistent reference framework for evaluating metabolite identity and measurement quality. The kit combines the Internal Standard, Long-Term Reference Standard, ClusterFinder software, and workflow guidance to help laboratories implement the approach within their LC-MS methods.
Correcting Variability. Revealing Biology. Metabolomics You Can Trust.
Contact IROA Technologies to discuss TruQuant’s suitability for your samples, analytical platform, and research objectives.