How to Accelerate Your Lab Operations With Modern LC Systems
App Note / Case Study
Published: October 1, 2026
Brought to you by
Thermo Fisher Scientific
Thermo Fisher Scientific is the world leader in serving science. They provide cutting-edge technologies, innovative solutions and comprehensive services to a diverse range of industries, including pharmaceuticals, biotechnology, academia and healthcare. Their commitment to excellence and customer satisfaction drives them to continually push the boundaries of science and technology.
Credit: Thermo Fisher Scientific.
Pharmaceutical QC labs can spend hours running assay, impurity, and preservative tests as separate chromatography methods.
Newer UHPLC systems can bring these analyses together in a single method while supporting existing workflows. This flexibility allows straightforward modernization of legacy HPLC methods by taking advantage of modern column technologies that can handle higher backpressures.
This case study shows how one pharmaceutical laboratory cut total analysis time from more than 2 hours to 24 minutes by modernizing its methods.
Download this case study to see how:
Separate assay, impurity, and preservative analyses were combined into a single UHPLC method A modernized method reduced sample and mobile phase preparation time by 50% The transition generated an estimated $2,750 in yearly savings across 45 syrup lots
Streamlining productivity and reducing costs:
Opella's transition to Vanquish Flex UHPLC
Case study | 004274
Pharma
Introduction
Opella Healthcare, headquartered in Neuilly-sur-Seine, France, benefits from its
long-standing pharmaceutical heritage and specializes in the development,
manufacturing, and commercialization of consumer health products. With operations
spanning multiple countries and a strong legacy of scientific excellence inherited
from Sanofi, Opella Healthcare is committed to delivering high-quality, accessible
healthcare solutions.
As a continuation of the partnership initiated with Sanofi in 2021 to upgrade their
liquid chromatography (LC) instruments with Thermo Fisher Scientific technology, this
collaboration now extends to Opella. The partnership helped Opella boost productivity
and reduce costs, while providing Thermo Fisher Scientific with valuable insights into
how their instruments perform in both research and quality control labs.
The Ocoyoacac site in Mexico is focused on consumer healthcare products,
manufacturing over-the-counter syrups and multivitamin supplements. As previously
executed at an Opella site in France,1 Opella's Ocoyoacac site replaced outdated
high-performance liquid chromatography (HPLC) systems with Thermo Scientific™
Vanquish™ Flex Ultra-High-Performance Liquid Chromatography (UHPLC) Systems to
enhance lab efficiency. With these new systems, several important analytical methods
have been modernized, complying with regulatory recommendations for updating
equipment and improving method management.
Keywords
(U)HPLC, (Ultra)high-performance
liquid chromatography, method
development, method transfer,
method modernization, solvent waste
reduction, cost savings
The International Council for Harmonisation (ICH) Q14 guidance,2
adopted in November 2023, advises on the continuous
improvement of analytical procedures through equipment
upgrades and new technologies to boost specificity, precision,
and accuracy.
Updates to the United States Pharmacopeia (USP)
Chapter <621>3 allow flexibility in modernizing liquid
chromatographic methods. These changes let users adjust
column dimensions, flow rates, and other parameters for isocratic
and now gradient methods without the need for re-validation.
Instrument and method modernization
The Ocoyoacac site produces 45 batches of a specific syrup
per year, each requiring liquid chromatography testing for assay,
impurity, and preservative analysis. Originally, the API and
related substances assay method and the preservative method
were developed separately and submitted to the authorities
as two independent analytical methods (Figures 1A and 1B).
This resulted in a significant amount of analysis time, sample
preparation, and data processing.
The site operates their HPLC systems under Waters™ Empower™
CDS software, which was a consideration during the feasibility
stage of the partnership. The Thermo Fisher team provided
assurances that the implementation of Vanquish systems into an
Empower network would be smooth and straightforward. This
proved to be the case, ensuring that existing workflows were not
disrupted. This seamless integration allowed users to continue
processing data in the same manner as before, maintaining
consistency and reliability in their analytical processes.
Vanquish Flex UHPLC systems were chosen for their ability to
perform both HPLC and UHPLC methods, providing the site
flexibility in the methods that they could run on the systems. This
enabled legacy HPLC methods to be readily modernized to take
advantage of modern column technologies and handle the higher
backpressure generated by these methods.
The goal was to reduce overall analysis time and the number of
instruments used. To achieve this, the legacy methods have been
combined into a single UHPLC method. Figures 1A, 1B, and 1C
compare the chromatograms from the previous legacy methods
to the modernized combined one. The use of the Vanquish Flex
UHPLC system resulted in a significant reduction in the total run
time from two hours and twenty minutes to twenty-four minutes,
which means a savings of one hour and fifty-six minutes and thus
shortens the analytical run time by approximately 80% (Table 1).
Figure 1. (A) Assay and impurities – Chromatogram before method
modernization; (B) Preservatives – Chromatogram before method
modernization; (C) Combined assay/impurity/preservatives after
method modernization on the Vanquish Flex UHPLC system.
A
C
B
2
Figure 2 demonstrates the productivity gain of the modernized
Vanquish Flex UHPLC method compared to the legacy method
when running a comparative study of four lots of syrup.
The estimated yearly savings after the transition to the
Vanquish Flex UHPLC system is given in Table 2. The overall
savings (including labor and solvents) is estimated to be $2,750
per year.
Table 1. Legacy method versus Vanquish Flex UHPLC method
run time.
Legacy method run time (min) Vanquish Flex UHPLC
method run time (min)
Assay and impurity Preservatives Assay and impurity and
preservatives
40 100 24
Figure 2. Summary of efficacy gain in analysis time and solvent
consumption for the modernized Vanquish Flex UHPLC method.
Values are calculated based on four lots of syrup.
The transition from the previous double sample and solvent preparations to a single
preparation by switching to Vanquish Flex UHPLC instruments significantly increased Opella's
productivity and drastically reduced costs.
Table 2. Estimated yearly savings after the transition to a
Vanquish Flex UHPLC system.
Labor time (days) Solvent consumption (L)
Sample
prep.
Data
processing
Sample
prep.
Chromatographic
method
Yearly
savings* 5.6 3.5 18 7.4
Total 9.1 25.4
*Yearly savings from 45 lots of syrup
Feedback from Opella's laboratory users indicates that the
Vanquish Flex UHPLC is a robust system, thanks to the use of
Thermo Scientific™ Viper™ Fittings. These fittings allow for easy,
quick connections without leaks, ensuring reliable performance.
Additionally, the same Viper fittings can be used for both HPLC
and UHPLC applications, simplifying method transfer and
increasing the versatility of the instrument.
The modernized method has been easily transferred from the
support lab to the QC lab, enabling savings and productivity
improvements from now on. Since the transfer, only one
instrument has been used to run these sequences, instead of two
as before.
In addition to measurable gains, there are further benefits that
support the corporate social responsibilities of both Opella and
Thermo Fisher Scientific. These benefits include decreasing
environmental impact and energy usage while promoting public
health. By shortening method durations and utilizing energyefficient
systems, energy consumption is reduced. Cutting
down on chemical use and waste disposal aids in environmental
conservation. Additionally, limiting exposure to solvents improves
the health and safety of analysts, lowering the risk of occupational
health problems and accidents.
In addition to this impressive instrument runtime savings, the
laboratory labor time is also directly impacted by this modernized
method. During the development phase, the sample preparation
was simplified, reducing both the worktime and solvent
consumption. Using only one instrument instead of two reduced
the sample and mobile phase preparation time by 50%. The data
processing time was also reduced by 50%, representing another
savings of 3.5 days of labor per year.
3
General Laboratory Equipment. Not For Diagnostic Procedures. © 2025, 2026 Thermo Fisher Scientific Inc.
All rights reserved. All trademarks are the property of Thermo Fisher Scientific and its subsidiaries unless otherwise specified. Opella
is a trademark of Sanofi. Waters and Empower are trademarks of Waters Corp. This information is presented as an example of the
capabilities of Thermo Fisher Scientific products. It is not intended to encourage use of these products in any manner that might
infringe the intellectual property rights of others. Specifications, terms and pricing are subject to change. Not all products are available
in all countries. Please consult your local sales representative for details. CS004274-EN 0626
Learn more at thermofisher.com/methodmodernization
Conclusion
Although upgrading HPLC instruments and methods might
seem daunting at first, recent technological advancements
and regulatory requirements for effective analytical procedure
lifecycle management have driven companies to modernize
their equipment. The collaboration between Opella and
Thermo Fisher Scientific focused on replacing outdated HPLC
systems with modern UHPLC systems. This partnership
showcases the advantages laboratories can gain from such an
upgrade. These advantages encompass improved environmental
health and safety, decreased instrument usage, lower solvent
consumption, reduced sample preparation time, and a smaller
environmental footprint. In the end, this partnership lead to
substantial cost savings and increased productivity and helped to
meet regulatory standards.
Vanquish systems installed within an existing Empower CDS
network have been proven to operate exceptionally well,
positioning Vanquish systems as an excellent solution for
instrument modernization.
Acknowledgments
We would like to extend our gratitude to the dedicated team
at Opella for their exceptional work: Anahi Lujano Mireles,
Oscar Gutierrez, Andrés López, Ana Laura Castillo, and
Tania Montes. Additionally, we would like to acknowledge the
outstanding support from the Thermo Fisher team, particularly
Daniel Compean, Sylvia Grosse, and Vincent Lelievre for their
collaboration and commitment, which have been instrumental in
achieving our goals.
References
1. Thermo Fisher Scientific Case Study 003059: How Sanofi increased productivity and
reduced costs and solvent usage, 2024.
2. International Council for Harmonisation of Technical Requirements for Pharmaceuticals
for Human Use, ICH Harmonised Guideline, Analytical Procedure Development Q14:
ICH_Q14_Guideline_2023_1130, 2023.
3. USP General Chapter <621> Chromatography. United States Pharmacopoeia
Convention Inc., Rockville, MD.
"The column compartment of the Vanquish Flex
UHPLC system is highly flexible, accommodating
columns up to 30 cm in length while providing
reproducible temperature control with still air or
forced air heating modes. The instrument also
provides excellent injection repeatability, ensuring
consistent results and therefore minimizing sample repetitions. Its intuitive design includes
LED lights that clearly indicate the status of the equipment, making it user-friendly and
efficient."
—Ana Laura Castillo (Chemical Analyst) and Andrés López (QC Coordinator)