Seeing Advanced Therapies in a Different Light With Flow Cytometry
Through high-parameter analyses and extended techniques, flow cytometry has become a backbone technology in the cell and gene therapy pipeline.
In 1953, Watson and Crick published their proposed structure for DNA. Less than 70 years later, the US Food and Drug Administration issued its first approval of a gene therapy—a chimeric antigen receptor (CAR) T-cell therapy to treat the relapse of a rare blood cancer.
Since that approval in 2017, the subsequent decade has seen a rapid expansion of the cell and gene therapy sector, with dozens of approvals for cell and gene therapies being issued by regulators and hundreds more potential therapy candidates progressing through the development pipeline.
Growing in tandem with the rapid expansion of the cell and gene therapy space has been an urgent need for analytic technologies that are capable of providing adequate monitoring and quality control to ensure the safety and efficacy of these therapies.
Flow cytometry has emerged as a key tool in the development, manufacture, and testing of cell and gene therapies. The variety of available flow cytometry assays allows the technique to be applied across many different target cell types and cultures, for a variety of purposes. As a result, it has become an essential part of many cell and gene therapy manufacturing processes. Understanding the uses and limitations of flow cytometry assays in the advanced therapy space is an important aspect of practical therapy and process development.
Flow cytometry in the cell and gene therapy space
As a technique, flow cytometry is valuable as it allows researchers to perform rapid, multi-parametric analyses on single cells in solution. Cells are moved in a stream through a light beam or laser light, where their light-scattering and fluorescence emissions are detected and measured by series of lenses, beam splitters, and filters.
From this, it is possible to analyze and differentiate cells based on their size and granularity, as well as through the presence of different fluorescent chemical compounds, known as fluorochromes or fluorophores. There is a wide variety of commercially available fluorochrome reagents that can be used to create fluorochrome-conjugated antibodies, proteins, and probes. Through multiplexed fluorochrome panels using a combination of different classes of fluorescent probes, it is possible to evaluate the purity and viability of cell therapies, as well as potency-related markers, CAR expression for CAR T-cell therapies, immune reconstitution, and cell transduction in gene therapy.
“Flow cytometry is suited to looking for the expression of proteins which can be on the surface or in the cytoplasm or in the nucleus of cells, the expression of fluorescent proteins which may have been genetically engineered into cell lines, and the ability to look at functional assays, for example, the pH of cells or cytotoxicity assays,” Derek Davies, an independent consultant and trainer in flow cytometry, told Technology Networks.
With the flexibility afforded by the array of fluorochromes and assay types available, flow cytometry can be applied for investigative and quality control purposes at many different stages in the cell and gene therapy development pipeline. In target discovery and validation, it can be used to analyze heterogeneous cell populations and support the screening of large candidate libraries. In preclinical studies, flow cytometry is applied to visualize in vitro and in vivo transgenic expression, as well as to evaluate immunogenicity and unwanted cross-reactivity. In clinical trials, the technique can be used to study the long-term persistence of engineered cells in patient samples, as well as clinical follow-up and immunomonitoring.
“Cell sorting, particularly single-cell sorting for clonal expansion, [also] plays a big role in gene therapy,” Davies noted.
Fluorescence-activated cell sorting (FACS) is a specialized subset of flow cytometry which can physically separate individual cells based on their light-scattering and fluorescent properties. For cell therapies, such as CAR T or stem cell therapy, FACS can be applied for ex vivo quality control as a way to remove over-differentiated or otherwise contaminating cells (such as residual tumor cells) from the final product. In gene therapy, FACS can help to measure and select successfully edited or transduced cells, enabling further clonal expansion or downstream genomic analyses.
“Often the selection of cells to sort is based on only one or two antigenic targets,” Davies explained. “Particularly with clonal expansion, it is very important that a cell sorter sorts only one cell of interest to a well, and this has meant that the operators of cell sorters have to be more rigorous in the way cells are selected, so that it maximizes the chances of there being just a single cell per well. An advantage of flow cytometry is the purity at which cells can be identified or sorted, so researchers can be very confident of the cells that they retrieve.”
Expanding cell therapy analysis with spectral flow cytometry
While the ability to do multi-parameter analyses is a core strength of flow cytometry, it can also present a significant challenge; in some cases, overlap in the emission spectra of different fluorochromes may produce a “spillover” effect which can make the resultant spectrum difficult to resolve.
Traditionally, this was dealt with by either using self-limiting assay designs or through hardware advancements, such as more sophisticated optical filter arrangements on the front-end of the instrument. Then, in 2004, a research group led by Prof. J. Paul Robinson at Purdue University presented a new approach they dubbed spectral flow cytometry.
“I think the main advantage [of spectral flow cytometry] is the ability to increase the complexity of assay design, bringing a significant increase in data complexity. This has itself driven significant increases in our ability to introduce advanced algorithms to the analytical process,” Prof. Robinson, distinguished professor of cytometry at Purdue University, told Technology Networks.
The main difference between traditional and spectral flow cytometers lies in the detection systems they use. Traditional cytometers use mirrors and optical filters to separate and detect light in a strictly one narrow-band detector–one fluorochrome ratio, whereas spectral flow cytometers use multiple detector arrays to capture the full emission spectrum of each fluorochrome. This avoids the need for a complex optical filter system, while also supporting high-parameter panels using 40 or more dye colors; traditional detectors are normally limited by the number of unique detectors they have.
In the advanced therapies space, the ability to measure many dozens of markers in a single run using spectral flow cytometry can enable deeper immune profiling for cell and gene therapies. Such immunogenicity assessments are a critical part of the journey to regulatory approval for these therapies.
“The ability to provide very high parameter data sets using relatively small volumes of blood is a huge boost to assay development across a variety of syndromes,” Robinson said.
“I see the partnership between spectral cytometry and advanced analytics as the most significant aspect of the technology. The future for clinical monitoring is high due to this combination of technologies.”
Challenges in flow cytometry for advanced therapies
As a technology, flow cytometry has advanced significantly since the development of the first laser “cytograph” system. However, there are still several challenges for the field to overcome.
“A slight drawback of flow cytometry is that often reference materials are not available,” said Davies. “Sometimes it is important to look at the actual level of antigen expression in terms of receptor numbers, which although is possible by flow cytometry, requires a good deal of work up.”
“The basic principles of flow cytometry remain unchanged in the past 50 years, but what has happened is we've seen improvements in virtually every aspect of the cytometer,” Davies continued. “One area where we still need to make improvements is in the detection of the photons that are emitted from our fluorochromes. The detectors we currently use are relatively inefficient. We should be able to count exactly the number of photons that have come from the cell, but at present that is not possible. We await the introduction of single photon detectors which would be the next leap forward in quantitative flow cytometry.”
Robinson also picked out quantitation as being “the most important issue that has to be faced” in the field at present.“For decades the technology has called itself quantitative, but with exceptions, it fails to achieve that goal,” Robinson noted. “There are two reasons for this. First, the vast majority of the field has accepted the limitations and identified mechanisms that provide an adequate output that provides a more qualitative response.”
“The second issue is in the way the instruments are designed; the detection systems that are almost standard across the field make it quite difficult to introduce truly quantitative measures. Many attempts to solve this have been made, and they all provide some level of usefulness, but I do not see the majority of the field paying much attention to this issue. Some folks don't even think it’s an issue. I think it’s one that must be solved to move the field forward, as true quantification is something that I think is necessary. When you introduce advanced algorithms that are manipulating data sets, you want them to be truly quantitative.”
However, despite these drawbacks, Robinson remains confident that flow cytometry will continue to play its role as a backbone of cell and gene therapy analysis over the decades to come.
“What I can say is that the overall technology now available in the field has advanced significantly over the past several years. Therefore, I am confident that its use in every area—including cell and gene therapy—will provide more useful, more accurate, and more detailed information than ever before,” Robinson concluded.