We've updated our Privacy Policy to make it clearer how we use your personal data. We use cookies to provide you with a better experience. You can read our Cookie Policy here.

Advertisement

Product
Advertisement

Accelerate Gene Therapy Development With the ZenoTOF 7600 System

Accelerate Gene Therapy Development With the ZenoTOF 7600 System


The ZenoTOF 7600 system is an innovative, accurate mass spectrometry solution that combines powerful fragmentation technology with highest MS/MS sensitivity.

Driven by the power of electron-activated dissociation (EAD) coupled with the Zeno trap, this fragment-centric revolution unlocks sensitivity gains, allowing you to uncover new information with certainty in your results to make better-informed decisions, faster.

Detect many more descriptive ions in every experiment and access a spectrum of tuneable fragmentation techniques to unlock new perspectives for every molecule, in every experiment.

ZenoEAD allows you to fine tune the electron energy, accessing multiple fragmentation mechanisms that can be applied to a variety of molecules and charge states, including large molecules, peptides, oligonucleotides, lipids and small molecules. Explore how you can:

- Understand your lipid raw material and lipid nano particle (LNP) quality
- Comprehensively characterize relevant analytes at very low abundances in a single experiment
- Elucidate structures of ionizable lipids and their impurities with unprecedented structural depth


Product Specifications
Footprint Reliable and robust accurate mass benchtop MS system. Requiring very little lab space, occupying occupies less lab space than any other HRMS on the market today. H: 112cm D: 114cm W: 57cm
Software Powered by SCIEX OS mass spectrometry software, intuitive algorithms and automation enable you to make informed decisions quickly. Transform your LC-MS/MS workflows with remarkable quantitative usability, efficiency, and integrity that streamlines your entire lab.
Ion sources Advanced source designs that limit contamination for maximized uptimes with enhanced usability features from a simplified engineering design built from the legacy of the Turbo V source. Coupled with the calibration delivery system for fast, automated calibrations across the flow rate ranges.
TOF N-optic TOF design provides optimal mass accuracy and resolution without compromising sensitivity. Heated TOF path & drone heaters Mass Range: 40 to 40 kDa in TOF Resolution: ≥ 42k at m/z 956 MS/MS Speed: 133 Hz Mass Accuracy: <2 ppm RMS Ext., <1 ppm RMS Int Positive & Negative LDR:>5 orders Inter-scan LDR
EAD cell Highly tunable electron activated dissociation (EAD) allows for a range of free electron- based fragmentation mechanisms within one device.
Q0 Design Improved ion optics design for ion capture and transmission, with easy access for maintenance.