Improving Animal Welfare: The Role of Multimodal Preclinical Imaging
Integrated imaging technologies are improving data quality while supporting the 3Rs in animal research.
Evolving ethical standards and tightening regulatory requirements are increasingly influencing preclinical research. In this context, where animal research remains essential for understanding complex biological systems and developing new therapies that tackle human disease, preclinical imaging (PCI) has become a key enabler of both scientifically precise and ethically responsible study design, while also supporting the advancement of life-saving therapeutics.
Multiple imaging approaches, including magnetic resonance imaging (MRI), micro-computed tomography (microCT), positron emission tomography (PET), single photon emission computed tomography (SPECT), bioluminescence imaging (BLI), and fluorescence imaging (FLI), may be utilized alone or integrated into a multi-modal solution to generate richer, more comprehensive datasets from fewer animals.
By enabling information-rich data collection, multimodal imaging aligns closely with the 3Rs framework for animal welfare. As these technologies continue to develop, the integration of imaging platforms with robust data management and complementary research models is becoming fundamental to conducting efficient, ethical, and impactful preclinical research.
The principles of the 3Rs
Developed in The Principles of Humane Experimental Technique, the internationally recognized 3Rs framework of replacement, reduction, and refinement guides a responsible approach to improving animal welfare while maintaining scientific research quality.
- Replacement: Development of alternatives to animal models where possible (e.g., cell lines, organoids, and other in vitro systems). However, whole-organism models remain necessary for studying systemic interactions such as immune, hormonal, and metabolic responses.
- Reduction: Obtaining robust data from fewer animals or maximizing information per animal reduces the number of animals used while minimizing inter-animal variability through better experimental design, and avoids additional testing.
- Refinement: Improving procedures to minimize stress, pain, and invasiveness using techniques that allow monitoring without repeated invasive sampling.
Over recent decades, significant advances have been achieved in PCI technologies that support the 3Rs, specifically reduction and refinement. These include in vivo imaging, particularly multimodal methods that enable non-invasive data acquisition alongside the development of non-animal models, and increasingly sophisticated computational and statistical methods that enhance both experimental design and data analysis.
However, despite the growing availability of alternative approaches, animal studies continue to play a critical role in investigating complex biological systems that cannot yet be fully reproduced using in vitro or in silico methods.
Benefits and challenges of multimodal imaging
Although individual imaging modalities each provide meaningful insights, their combined use can expand the scope and resolution of data generated in a single study, as different techniques provide distinct yet complementary capabilities:
- BLI/FLI: Easy to use, high throughput, and early cellular-level detection with molecular probes.
- MRI: Soft tissue contrast, plus many functional and molecular methods.
- PET/SPECT: High molecular sensitivity, especially for metabolism and cell/molecular receptors.
- microCT: High-resolution anatomical structure of mineralized tissue (including bone and teeth), lungs, and adipose tissue.
By integrating these modalities, it is possible to correlate anatomical, functional, and molecular datasets within the same animal and study, enabling a more holistic understanding of disease progression and treatment response.
Widespread adoption has, however, been constrained by practical challenges. Variability in instrumentation, workflows, and data formats has historically complicated workflow integration and data harmonization across modalities.
Implementing multimodal workflows
Employing multimodal imaging workflows frequently necessitates transferring animals between different instruments, which can prolong handling, increase stress, and introduce positional variability that affects data consistency. The need for repeated anesthesia, along with challenges in aligning datasets, further complicates experimental execution.
To address these limitations, novel solutions are emerging that enable a more seamless integration across imaging platforms (Figure 1). For instance, cradle-based inlay systems allow animals to be moved between instruments without disrupting their positioning, minimizing variability and supporting the acquisition of more accurate, synchronized datasets.1

Figure 1: Lung tumor mouse model imaged using a cradle-based inlay system provides complementary information from microCT, BLI, PET, and MRI. Credit: Bruker BioSpin.
Using multiple imaging modalities within the same animal reduces the need for repeated handling and associated procedural stress, while limiting variability that occurs from repositioning and inter-animal differences. This approach produces integrated datasets that capture molecular, functional, and anatomical information in a unified framework. The outcome is a more streamlined, animal-conscious workflow that aligns with the 3Rs principles, while improving data robustness and reproducibility.
Diversifying research approaches beyond animal models
In parallel with developments in imaging, alternative research strategies—including organoid systems, in vitro assays, and computational modeling—are continuing to evolve. These methods are particularly valuable in early-stage discovery, where they can help reduce dependence on animal-based studies.
These approaches are not yet capable of fully capturing the complexity of whole-organism biology. Critical interactions across immune, endocrine, and metabolic systems remain challenging to replicate outside a living organism.
Consequently, preclinical research is moving toward a hybrid framework that integrates non-animal methodologies for initial screening with carefully designed in vivo studies for comprehensive biological validation. High-throughput screening models can generate predictive insights into human biology, disease mechanisms, and therapeutic efficacy before being evaluated in more complex animal models. Within this paradigm, multimodal imaging technologies play a pivotal role by enabling richer, longitudinal data collection from fewer animals.
This integrated approach is supported in a study assessing CAR T-cell therapies for ovarian cancer. Organoid models were used for preliminary evaluation, followed by confirmation in human ovarian cancer xenograft models in NSG mice. BLI supported non-invasive, longitudinal monitoring of treatment response within the same animals, reducing overall animal usage while improving data consistency. Such studies highlight a shift toward more efficient, ethical, and data-driven preclinical research frameworks.
Transforming preclinical models
Multimodal PCI is redefining how animal studies are designed and conducted, offering a powerful means of aligning scientific research with ethical responsibility. By enabling longitudinal, non-invasive data collection and integrating anatomical, functional, and molecular insights within the same subject, PCI directly supports the principles of reduction and refinement while enhancing data quality and reproducibility.
Although challenges remain in workflow integration and standardization, continued technological innovation is rapidly addressing these barriers with the convergence of advanced imaging technologies, alternative models, and robust data infrastructures. Together, these approaches enable more informed decision-making, reduce reliance on animal use, and accelerate the development of effective therapies.
References:
1. Van Praagh A, Ballieu P, Bahadur A, Granlund K, Madi S, Mattingly M, et al. An experimental cradle inlay system facilitates multimodal optical, PET, microCT, and MRI co-registrations and multiparametric analyses in a colorectal cancer mouse model. Presented at the World Molecular Imaging Congress (WMIC) 2025, Anchorage, Alaska, 29 September–3 October 2025; Abstract 299.