Quantitation Solutions for Every Step of Pharmaceutical Development
How To Guide
Published: May 28, 2025

Credit: SCIEX
The pharmaceutical industry demands precise, reliable quantitation throughout the entire drug development pipeline, from initial compound screening to final quality control (QC).
Older analytical systems can struggle with complex matrices and low-abundance analytes, making it harder to meet the stringent regulatory requirements that govern pharmaceutical development
This guide provides an overview of quantitation solutions that provide the sensitivity, robustness and compliance-ready capabilities needed to accelerate drug development while maintaining the highest analytical standards.
Download this guide to learn:
- How to overcome analytical bottlenecks across discovery, development and QC workflows
- Which analytical approaches deliver optimal results for small molecules versus large molecules
- Best practices for implementing compliance-ready solutions that streamline regulatory processes
Pharmaceutical
quantitation
solution guide
From discovery to QC, SCIEX is on your side
2
| sciex.com
3
Solution guide for pharmaceutical quantitation Introduction Discovery Development
(small mol)
Development
(large mol)
Regulatory
solutions
QA/QC and
lot release Products
Contents
04 Introduction
01 Discovery
08 Introduction
10 Biomarker quantitation
12 Compound quality assessment
14 HTS for small molecules
16 HTS for large molecules
18 Introducing the Echo®
MS+ system
20 Conclusion
02 Development (smal mol)
24 Introduction
26 Quantitation by high-resolution
mass spectrometry
32 ADME-Tox
34 Biomarker quantitation
36 Bioanalysis of:
36 Glucagon-like
peptides (GLP-1)
38 Peptides and
cyclic peptides
40 Nucleic acids and
oligonucleotides
42 Targeted protein
degraders
44 Conclusion
03 Development (large mol)
48 Introduction
50 Antibody drug
conjugates (ADCs)
52 Antibodies and peptide
surrogates
54 Biomarker quantitation
of large molecules
56 Cell culture
58 Proteins
60 Conclusion
04 Regulatory solutions
64 Introduction
66 Instrument qualification
68 Software validation
70 Audit preparations
72 Conclusion
05 QA/QC and lot release
76 Introduction
78 Impurity analysis
80 Nitrosamines
82 Extractables and leachables
84 Conclusion
06 Products
88 Triple quadrupole systems
90 Quadrupole time-offlight systems
92 Echo® MS+ system
94 Software and services
96 Conclusion
4 | sciex.com 5
Solution guide for pharmaceutical quantitation Introduction Discovery Development
(small mol)
Development
(large mol)
Regulatory
solutions
QA/QC and
lot release Products
Introduction
We understand you are busy, needing to prioritize
running instruments, reporting results and
managing your laboratory to meet deadlines.
We created this solution guide to explain how
SCIEX systems fit in the drug development
pipeline to save you time evaluating options.
This guide covers bio/pharmaceutical
quantitative assays from discovery to
QA/QC, for large and small molecules.
Happy reading!
Request information
Discovery
01
Featuring
• Biomarker quantitation
• Compound quality assessment
• HTS for small molecules
• HTS for large molecules
8 | sciex.com 9
Solution guide for pharmaceutical quantitation Introduction Discovery Development
(small mol)
Development
(large mol)
Regulatory
solutions
QA/QC and
lot release Products
Introduction
Drug discovery
Pre-clinical
development
Clinical
development
Regulatory
approval
Result
5,000,000 compounds
500 compounds
5 compounds
FDA
1 approved
drug
Featured solutions
Complex samples
For complex samples requiring chromatographic
separation before detection, our recommendation
is the ExionLC AE system with SCIEX Triple Quad
6500+ system for excellent sensitivity.
High-throughput screening (HTS)
When you have analytes in simpler matrices, we
recommend the Echo® MS+ system. The Echo® MS+
system offers contactless sample ejection at a rate
of up to 1 sample per second. Samples are detected
by our trusted MS instruments, using either the SCIEX
Triple Quad 6500+ system or ZenoTOF 7600 system.
Bring high-quality data to your drug discovery
process quickly and simply.
Regardless of scale, our integrated systems include
software and services that come together as total
solutions to deliver high-quality, rapid results for
confident, data-driven decision making. Get the information
you need to make go/
no-go decisions as
quickly as possible
in the drug discovery
phase of your work.
10 | sciex.com 11
Solution guide for pharmaceutical quantitation Introduction Discovery Development
(small mol)
Development
(large mol)
Regulatory
solutions
QA/QC and
lot release Products
Biomarker
quantitation
Small molecule
High-resolution mass spectrometry
peptide quantitation for
biomarker verification using
the ZenoTOF 7600 system.
Learn how MRMHR can be used to achieve
a lower limit of quantitation (LLOQ) of
0.02 fmol/µL for peptides spiked into a
background of 400 ng cell lysate digest.
Large molecule
Sensitive multiplexed quantification
of protein biomarkers for early drug
discovery and development.
Reach outstanding accuracy, precision
and linearity for the quantitation
of multiple protein targets in
plasma at low-ng/mL levels.
Bringing drug candidates through the development pipeline
has multiple complicated steps. Improving the efficiency and
accuracy of results can simplify and accelerate this process.
Our systems provide in-depth coverage that enables you to
characterize and confidently quantify biomarkers, including
low-abundance analytes. With different technology options for
specific needs, SCIEX can help you get the answers you need.
• Achieve confident answers in hours
instead of dayss instead of days
• Confidently characterize and quantify small
biomarkers with robust, sensitive analyses
• Improve workflows with support from
our dependable team of experts
Extracted ion chromatograms (XICs) for the summed +2y6 and
+2y5 fragments of the ANELLINVK tryptic peptide of ADH1.
XICs were used for the quantitation of hSFTP-A and hSFTP-D.
12 | sciex.com 13
Solution guide for pharmaceutical quantitation Introduction Discovery Development
(small mol)
Development
(large mol)
Regulatory
solutions
QA/QC and
lot release Products
Compound quality
assessment
Compound quality
assessment
High-speed compound quality assessment
using acoustic ejection mass spectrometry
Read about how the Echo® MS+ system can
be used to screen 45 compounds within
4 minutes using positive and negative
polarity. All analyses are completed in
SCIEX OS software for simplified system
control, data acquisition and processing.
Fully understand the identity of the target
compounds within your compound library with highthroughput mass spectrometry-based testing.
Reduce the risk of sending degraded or incorrect
drug candidates for further development within
your organization, saving time and money.
• Identify and confirm the presence of target compounds in
libraries with using acoustic ejection mass spectrometry
(AEMS) for accurate and reproducible results
• AEMS allows for sample throughput of up
to 1 sample per second and data reliability
provided by mass spectrometry detection
• Easily report results with an end-to-end workflows
Representative XICs and TOF MS spectra for compounds
detected using positive and negative ionization modes.
14 | sciex.com 15
Solution guide for pharmaceutical quantitation Introduction Discovery Development
(small mol)
Development
(large mol)
Regulatory
solutions
QA/QC and
lot release Products
HTS for small
molecules
Automated HTS
An automated, real-time measurement
of kinetic hydrolysis of glucuronide.
Discover how real-time measurements
of glucuronide hydrolysis are possible
using the Beckman Coulter® Life Sciences
Biomek i7 automated liquid handler to
prepare and perform a kinetic study before
transferring the samples to the Echo® MS+
system to quantify the analytes of interest.
Reduce complexity
of assays
High-resolution, specific analysis
of arginine and citrulline.
Read about how the Echo® MS+ system
can rapidly quantify both arginine
and citrulline in a single analysis with
minimal sample preparation.
Gather high-quality data while reducing reagent
and sample costs with high sample throughput for
critical go/no-go decisions during drug discovery.
The Echo® MS+ system enables you to run thousands
of samples and report results on the same day.
• Reduce analytical bottlenecks with a sampling
rate of up to 1 sample per second
• Minimize sample consumption, using
as little as 2.5 nL of sample
• Screen millions of compounds with AEMS
to identify bioactive compounds that inhibit
enzyme activity during drug discovery
Rate of codeine production from the 50 ng/mL (green) and the
250 ng/mL (dark blue) codeine-6-glucuronide samples.
Observed arginine peak area ratios determined by the citrulline
common and unique product ions. The peak area ratios were
determined at concentrations of 1000 µM, 500 µM and 250 µM.
16 | sciex.com 17
Solution guide for pharmaceutical quantitation Introduction Discovery Development
(small mol)
Development
(large mol)
Regulatory
solutions
QA/QC and
lot release Products
HTS for large
molecules
Automated HTS
Determine optimal buffer concentration
and compatibility for high-throughput
intact protein analysis.
Read about how the Echo® MS+
system can be used to screen 16
buffers at 10 concentrations in
approximately 11 minutes.
Protein analysis is inherently challenging due to the
complexity of the sample. The selection of a buffer
that maintains the activity and folding pattern of
the protein is important to allow accurate data to be
collected. Additionally, when mass spectrometry is the
analytical technique of choice, high salt concentrations
in the buffers can cause ionization suppression.
The Echo® MS+ system alleviates some of these challenges:
• With a sampling rate of 4 seconds per sample
• Sample dilution and low sampling volumes
reduce the impact of salt
16 biologically relevant buffers
Buffer component
Concentration
10µM Myglobin
PBD: 1MBN
18 | sciex.com 19
Solution guide for pharmaceutical quantitation Introduction Discovery Development
(small mol)
Development
(large mol)
Regulatory
solutions
QA/QC and
lot release Products
Introducing the
Echo® MS+ system
When the quantity of samples is your challenge, break
through with the Echo® MS+ system. It gives you highquality data, analytical flexibility and high sample
throughput so you can make informed decisions today.
These benefits are made possible with recent
innovations to the hardware and software.
The comparison of AEMS system robustness. A comparison is shown for the %CV per
plate equivalent for datasets without (blue) and with (orange) the OPI port wash.
High-throughput screening of buffer types.
Technology
innovations
Optimizing robustness for highthroughput screening.
The introduction of the Echo® MS+
system brought new features to the
technology. The introduction of the Open
Port Interface (OPI) port wash increased
the number of samples the system
can run before cleaning is required.
Method
development
Automated, rapid method
optimization and buffer screening.
See how method development time
can be reduced to minutes based on
instrument settings to buffer selection.
In minimal time, you can be sure you
have the best settings for your analysis.
20 | sciex.com 21
Solution guide for pharmaceutical quantitation Introduction Discovery Development
(small mol)
Development
(large mol)
Regulatory
solutions
QA/QC and
lot release Products
Conclusion
Easily collect the data you need from compound
screening to lead optimization to make informed go/
no-go decisions for your drug candidates.
We can ensure a smooth and efficient transition
to state-of-the-art mass spectrometry solutions
with access to an expert-level support team.
Selecting the right system for
bioanalytical quantitation.
Investing in a new LC-MS system is not
an easy decision, especially if you have a
range of analytical requirements in your
laboratory. This blog is intended to help
you choose the right system for your
pharmaceutical drug development needs.
Want to accelerate your drug
discovery workflow?
Bringing a new drug to market is a costly
and complex process. With potentially
hundreds of thousands of new compounds
to screen during drug discovery, sample
throughput is a common bottleneck
for pharmaceutical companies. So
how do you overcome this barrier?
5 Reasons to choose the Echo® MS system
for high-throughput drug discovery.
Have you thought about introducing new
technology into your high-throughput drug
discovery lab? Here are 5 reasons the Echo®
MS system could make a difference for you.
Driving more sensitive bioanalysis using
accurate mass spectrometry.
Quadrupole-based liquid chromatography
coupled with mass spectrometry (LC-MS) has
been routinely adopted for the quantitation
of therapeutics in bioanalytical laboratories.
Advances in high-resolution spectrometry
have enabled it to become a complementary
option for quantitative bioanalysis. These
advances include greater selectivity, improved
mass resolution and the flexibility of timeof-flight (TOF) MS/MS for data analysis.
Additional links for discovery assays
Featuring
Quantitation by high-resolution
mass spectrometry
ADME-Tox
Biomarker quantitation
Bioanalysis of:
• Glucagon-like peptide (GLP-1) analogs
• Nucleic acids and oligonucleotides
• Peptides and cyclic peptides
• Targeted protein degraders
Development
(Small molecule)
02
24 | sciex.com 25
Solution guide for pharmaceutical quantitation Introduction Discovery Development
(small mol)
Development
(large mol)
Regulatory
solutions
QA/QC and
lot release Products
Introduction
Enhance your pharmaceutical development assays, while
simplifying method development and reducing training
needs. Our liquid chromatography-mass spectrometry
(LC-MS) solutions are intuitive, robust and sensitive.
All of our solutions are supported by complianceready software and trusted service professionals.
Accurately identify and monitor biomarkers,
active pharmaceutical ingredients (APIs) and
metabolites on a single software platform.
Featured applications and assays
• Featuring: Quantitation by highresolution mass spectrometry
• ADME-Tox
• Biomarker quantitation
• Bioanalysis of:
• Glucagon-like peptide (GLP-1) analogs
• Nucleic acids and oligonucleotides
• Peptides and cyclic peptides
• Targeted protein degraders
Featured solutions
Routine bioanalysis
Triple quadrupoles have been the gold standard for
bioanalysis for many years. The SCIEX Triple Quad
6500+ system offers trusted long-term performance.
For ultimate sensitivity and extended robustness, the
SCIEX 7500+ system is the solution of choice.
Complex samples
If you are challenged with coeluting compounds with
similar masses, analytes with complex structures, a
complex background with low abundant analytes or
analytes with a high molecular weight, a high-resolution
mass spectrometer is a great choice. The SCIEX X500R
QTOF system is the go-to system for most assays.
Alternatively, the ZenoTOF 7600 system can be used
for additional sensitivity and analytical horsepower.
26 | sciex.com 27
Solution guide for pharmaceutical quantitation Introduction Discovery Development
(small mol)
Development
(large mol)
Regulatory
solutions
QA/QC and
lot release Products
Introduction to quantitation by
high-resolution mass spectrometry
Filter out complex
background noise to see
more in your sample
Quantify coeluting
compounds with
similar masses
Easily quantify
high-mass and
complex analytes
28 | sciex.com 29
Solution guide for pharmaceutical quantitation Introduction Discovery Development
(small mol)
Development
(large mol)
Regulatory
solutions
QA/QC and
lot release Products
Benefits of high-resolution mass
spectrometry for quantitation
Triple quadrupole mass spectrometers have been
trusted for decades in pharmaceutical research and
development for their quantitative performance.
In recent years, there has been a move to highresolution mass spectrometry due to technology
advancements, which has provided more sensitive
and accurate quantitative performance. The appeal
of high-resolution mass spectrometers is their
ability to overcome the following challenges:
• Coeluting compounds with similar masses
• Separation of high background from low abundant analytes
• Quantitation of compounds with a high molecular weight
Quick system selection guide
Analyte is <2000
Da (typically)
Analyte is >2000
Da (typically)
Complex matrices for
which high levels of
selectivity are needed
ZenoTOF 7600 system
OR
X500R QTOFsystem
ZenoTOF 7600 system
OR
X500R QTOF system
For peptide
recognition modules
and peptides:
ZenoTOF 7600 system
or
X500R QTOF system
Absolute sensitivity
and performance:
SCIEX 7500+ system
Performance:
SCIEX Triple Quad
6500+ system
Absolute
performance:
ZenoTOF 7600
system
Performance:
X500R QTOF
system
Speak to a SCIEX
representative for
more detailed
discussions
Yes No
Analyte type
Do you need a system
that offers quantitative/
qualitative information?
Analyte and matrix
considerations
30 | sciex.com 31
Solution guide for pharmaceutical quantitation Introduction Discovery Development
(small mol)
Development
(large mol)
Regulatory
solutions
QA/QC and
lot release Products
Summary
We have worked with scientists across the drug development
pipeline for decades, leading the way in quantitative mass
spectrometry using quadrupoles. Our high-resolution
systems are easy-to-operate, with integrated analytical
solutions that can provide rapid and reliable quantitative
data with the added benefits of high resolution.
When you need support, SCIEX is here for you.
Fit-for-purpose solutions combining LC and highresolution MS enable quantitation in complex matrices with
excellent sensitivity and robustness, even at low levels.
32 | sciex.com 33
Solution guide for pharmaceutical quantitation Introduction Discovery Development
(small mol)
Development
(large mol)
Regulatory
solutions
QA/QC and
lot release Products
ADME-Tox
Complex samples, and possibly low-level analytes, are
common challenges that are faced every day by analysts
working on ADME-Tox studies. Our fit-for-purpose LCMS solutions enable pharmacokinetic parameters
to be monitored in complex matrices with excellent
sensitivity and robustness, even for low-dose, highly
potent drugs. Simplify the monitoring of ADME-Tox
parameters with compliance-ready SCIEX OS software.
• Perform ADME-Tox studies with confidence
using compliance-ready software
• Acquire reliable and sensitive bioanalytical data
using fit-for-purpose LC-MS solutions
Sub-picogram detection of fluticasone propionate in plasma.
Representative extracted ion chromatograms
(XICs) for formoterol in human plasma.
Regulated and non-regulated
ADME-Tox solutions for all
stages of the pipeline
Highly sensitive LC-MS/MS method for the
quantification of fluticasone propionate in human
plasma using the SCIEX QTRAP 6500 system.
Learn more about a highly sensitive and reproducible
method for quantifying fluticasone propionate
suitable for use in regulated bioanalytical labs using
a simple solid-phase extraction technique.
Low-level ADME-Tox analytes
A sensitive method for the quantification
of formoterol in human plasma.
Discover a quantitation method for low-dose, highpotency drug modalities combined with data acquisition
and processing options that are simplified with SCIEX
OS software, a 21 CFR Part 11-compliant platform.
Matrix blan Matrix Blank k 0.05 0.05 pg
pg/m/mL 0 L 0.2 .2 pg pg/m/mLL
34 | sciex.com 35
Solution guide for pharmaceutical quantitation Introduction Discovery Development
(small mol)
Development
(large mol)
Regulatory
solutions
QA/QC and
lot release Products
Biomarker
quantitation
Our systems provide in-depth coverage that enables you to
characterize and confidently quantify biomarkers, including
low abundant species. With different technology options for
specific needs, we can help you get the answers you need.
• Achieve confident answers in hours instead of days
• Confidently identify and quantify small
biomarkers with robust, sensitive analyses
• Improve workflows with support from
our dependable team of experts
Linear dynamic range for several acylcarnitine compounds.
Using Zeno DDA to determine the interference observed at ~3.7 minutes
Targeted
panel assays
High sensitivity quantification
of acylcarnitines using the
SCIEX 7500 system.
Discover how you can quantify
low-level acylcarnitine species
with high throughput, robustness
and reproducibility without
requiring derivatization.
Identify and
quantify unknowns
Identification and quantitation
of lipid biomarkers using
accurate mass spectrometry.
Balance accurate quantitative
performance with accuracy values
between 80–120% at all concentration
levels, with streamlined data
management for acquisition and
processing. Identification of lipid
biomarkers becomes a simple task
using the ChemSpider tool that is fully
integrated into SCIEX OS software.
XIC TOF MS
Formula
Finder
results
36 | sciex.com 37
Solution guide for pharmaceutical quantitation Introduction Discovery Development
(small mol)
Development
(large mol)
Regulatory
solutions
QA/QC and
lot release Products
Glucagon-like
peptides (GLP-1)
Highly sensitive analytical methods are required to understand
the pharmacokinetic and pharmacodynamic profiles of
GLP-1 analogs. Developing and running these methods is
challenging due to their low oral bioavailability and their
structure that yields poor ionization and fragment
• Quantify GLP-1 analogs in complex biological
matrices with outstanding reproducibility,
precision, accuracy and linearity
• Employ a single platform for streamlined data acquisition,
processing and management using SCIEX OS software
Structures of GLP-1 analogs. The left panel shows the structure of the target analyte,
semaglutide (A) and the right panel shows the structure of the internal standard, liraglutide (B).
LC-MS/MS
Low-ng/mL quantitation of
glucagon-like peptide-1 (GLP1) analog in rat plasma.
Discover options for a sensitive method
to quantify a GLP-1 analog, semaglutide,
in rat plasma with a lower limit of
quantitation (LLOQ) of 0.2 ng/mL.
Enhanced
robustness
Redefine bioanalysis with enhanced
robustness on the SCIEX 7500+ system.
This technical note demonstrates
the measurement of alprazolam,
sulfamethoxazole and diazepam in rat
plasma matrix over 10,000 injections,
with no divert valve. The SCIEX 7500+
system showed a >2x improvement
in robustness for this analysis
compared to the SCIEX 7500 system.
0
0.4
0.8
1.2
1.6
2
0 20 40 60 80 100 120 140
oit ar aer a kaeP
No. of SST injecons
%CV = 3.17% %CV = 3.42% %CV = 3.56%
SCIEX 7500+ system: 10,614 matrix injecons
0
0.4
0.8
1.2
1.6
2
0 2000 4000 6000 8000 10000
oit ar aer a kaeP
Number of matrix injecons
Sulfamethoxazole Diazepam Alprazolam
%CV = 5.17%
%CV = 4.27%
%CV = 4.22%
SST injecons
Rat plasma matrix injecons
A
B
Peak area ratio (raw peak area normalized to IS) from analysis of alprazolam
(orange), diazepam (blue) and sulfamethoxazole (grey) SST (A) and
rat plasma matrix (B) injections on the SCIEX 7500+ system.
38 | sciex.com 39
Solution guide for pharmaceutical quantitation Introduction Discovery Development
(small mol)
Development
(large mol)
Regulatory
solutions
QA/QC and
lot release Products
Peptides and
cyclic peptides
Peptide and cyclic peptide analysis presents unique
challenges compared to the analysis of a typical small
molecule. Peptides are large, complex molecules that
often contain multiple amino acids and post-translational
modifications.This complexity results in a higher degree
of structural variability, a wider dynamic range of
concentrations and multiple charging when analyzed by
mass spectrometry. Additionally, peptides are more prone to
sample loss, degradation and modifications during sample
preparation and analysis than typical small molecules.
Peptide:
Targeted panel
Reproducible targeted peptide profiling
using highly multiplexed MRM assays.
Read about a simplified method
development approach for largescale targeted peptide analysis. By
using our Scheduled MRM function,
retention times and MRM transitions
are automatically optimized to create
an acquisition method based on a few
key parameters provided by the user.
Chromatographic reproducibility for 30 min gradient runs.
Extracted ion chromatograms (XICs) of a matrix blank and LLOQ sample of human ANP.
Low-level cyclic
peptides
Low-pg/mL quantification of cyclic
peptides in rat plasma using microflow LC .
Read about how to achieve low-level
quantitation for human ANP at an LLOQ
of 0.01 ng/mL in rat plasma with %CV
values <12.3% at all concentration
levels across linear dynamic range
spanning 4.3 orders of magnitude.
• Our software allows you to automatically schedule multiple
reaction monitoring (MRM) functions, retention times
and MRM transitions for simple method optimization
• Easily develop and optimize quantitative workflows using
the M5 MicroLC system with seamless integration into
SCIEX OS software to enhance the sensitivity of a method
40 | sciex.com 41
Solution guide for pharmaceutical quantitation Introduction Discovery Development
(small mol)
Development
(large mol)
Regulatory
solutions
QA/QC and
lot release Products
Nucleic acids and
oligonucleotides
Synthetic nucleotide analysis is a complex pursuit
because these drugs combine the learnings from
nature’s mechanisms with sophisticated technology.
The diverse landscape of structural adaptations for
bases and backbones has the potential to treat diseases
with unprecedented specificity but also increases the
challenges for analyzing synthetic oligonucleotides.
• Complete sequence confirmation, impurity
identification, sizing and purity analysis with
cutting-edge analytical solutions
• High-quality results for therapeutic
oligonucleotides (antisense oligonucleotides,
siRNA, aptamers) help you advance medicine
Quantitation of
nucleic acids
Quantitative LC-MS solution
for targeted analysis of
cell culture media.
Discover options for the measurement
of polar and nonpolar analytes,
in addition to positive and
negative polarity components
within a single method.
Identify and
quantify unknowns
Characterization and
relative quantification of
oligonucleotide impurities.
See how robust data quality and high
mass accuracies provide confident
assignment of oligonucleotide FLP and
impurities using the Molecule Profiler
software. The use of this software
allowed straightforward relative
quantitation based on the TOF MS peak.
Confirmation of the sequence of the potential ASO-18PS2MOE
impurity with 1 isobutyryl protecting group on G.
Linear calibration curves of representative cell culture component
per group measured in positive and negative modes. %Area (of4.7e8)
42 | sciex.com 43
Solution guide for pharmaceutical quantitation Introduction Discovery Development
(small mol)
Development
(large mol)
Regulatory
solutions
QA/QC and
lot release Products
Targeted
protein degraders
Lead the development of novel targeted protein degradation
(TPD) therapeutics, such as proteolysis-targeting chimeras
(PROTACs). Bring novel drugs based on this new class of
compounds to market with analytical systems that enable
precise and accurate identification and quantitation of lowlevel targeted protein degraders, even in complex matrices.
Get to the important information quickly with fast, intuitive
and integrated data acquisition and processing software.
• Achieve sensitive quantitation of targeted protein
degraders with excellent accuracy and precision
• Comfortably work with complex matrices
Quantitation
Low-pg/mL quantification of
TL 13-112, a protein-targeting
chimera (PROTAC) in rat plasma.
See how it is possible to achieve
low-pg/mL level LLOQs for the
quantitation of PROTACs in rat plasma
with robust analytical performance.
These results were achieved in
combination with streamlined,
compliance-ready data management.
A sensitive method for the
quantification of the protein
targeting chimera (PROTAC),
TL 13-12, in rat plasma using
accurate mass spectrometry.
Achieve an LLOQ of 0.3 ng/mL for
the quantitation of TL 13-12 and
TL 13-22 in rat plasma using MS/
MS data acquisition. This approach
allows you to minimize sample volume
and sample preparation time.
Sub-ng/mL level quantitation was achieved for the PROTAC and its inactive control.
Representative XICs of the selective ALK degrader (PROTAC)
and its inactive control in matrix and at the LLOQ level.
44 | sciex.com 45
Solution guide for pharmaceutical quantitation Introduction Discovery Development
(small mol)
Development
(large mol)
Regulatory
solutions
QA/QC and
lot release Products
Conclusion
Simplify your pharmaceutical development assays to save time
and reduce the training needs of the scientists working in your
team. Our LC-MS solutions, including our software and trusted
services and support, are intuitive, robust and sensitive.
Selecting the right system
for bioanalytical quantitation
Investing in a new LC-MS system is not
an easy decision, especially if you have a
range of analytical requirements in your
laboratory. This blog is intended to help
you choose the right system for your
pharmaceutical drug development needs.
Sensitive LC-MS/MS approach for the
quantification of proteolysis- targeting
chimeras in a biological matrix
In this webinar, we explore a sensitive LC-MS/
MS workflow for quantifying PROTACs in a
biological matrix using the SCIEX 7500 system.
Enhancing quantitative sensitivity
in cerebrospinal fluid
This webinar discusses the sensitive quantitation
of LRRK2 at 10 pg/mL in human cerebrospinal
fluid. Dylan Bennett, a scientist at Neuron23,
shares the details of this LC-MS/MS methodology
for the sensitive analysis of this promising target.
Additional links for development assays
Easing the demands of a compliant
pharmaceutical laboratory
At SCIEX, we are proud to provide analytical
systems to the pharmaceutical industry. We work
hard to understand the demands of analytical
work and the processes required to develop
and manufacture drugs. This blog provides an
overview of some of the ways we are here to help.
Driving more sensitive bioanalysis
using accurate mass spectrometry
Quadrupole-based LC-MS has been routinely
adopted for quantitation in bioanalytical
laboratories, recently high resolution mass
spectrometry has become more popular.
This is due to greater selectivity, improved
mass resolution and the flexibility of timeof-flight (TOF) MS/MS for data analysis.
Identification and quantitation of lipid
biomarkers using high-resolution MS
In this webinar, our speaker discusses the
role of glucosyl and galactosyl ceramides as
biomarkers and how their misregulation can
be an identifier for various disease states.
Featuring
• Antibody drug conjugates (ADCs)
• Antibodies and peptide surrogates
• Biomarker quantitation of large molecules
• Cell culture analysis
• Proteins
Development
(Large molecule)
03
48 | sciex.com 49
Solution guide for pharmaceutical quantitation Introduction Discovery Development
(small mol)
Development
(large mol)
Regulatory
solutions
QA/QC and
lot release Products
Introduction
Featured solutions
LC-MS
The ZenoTOF 7600 system offers excellent
sensitivity and mass resolution for large molecule
quantitation. When additional sensitivity is required,
combine the ZenoTOF 7600 system with either the
ExionLC AE system or the M5 MicroLC system.
Software
SCIEX OS software offers an easy-to-use, complianceready software platform. Biologics Explorer software
delivers highly accurate and informative data for full
characterization of protein biotherapeutics.
Enhance your large molecule quantitative assays while
your large molecule quantitative assays while simplifying
method development and reducing training needs. Our liquid
chromatography and mass spectrometry (LC-MS) solutions
are intuitive, robust and sensitive, and our trusted services
and support help you get the most out of your investment.
Accurately identify and monitor molecules—
such as biomarkers, proteins and antibodies—
on a single software platform.
Featured applications and assays
• Antibody drug conjugates (ADCs)
• Antibodies and peptide surrogates
• Biomarker quantitation of large molecules
• Cell culture analysis
50 | sciex.com 51
Solution guide for pharmaceutical quantitation Introduction Discovery Development
(small mol)
Development
(large mol)
Regulatory
solutions
QA/QC and
lot release Products
Antibody drug
conjugates (ADCs)
Understand ADC drug loading profiles regardless of the
inherent heterogeneity and high molecular weight of these
molecules. Assess the quality of ADCs using drug antibody
ratio (DAR) information, so you are clear on what you have,
how much you have and whether it will be effective.
SCIEX software and solutions enable:
• Acquisition and tracking of DAR changes
• High-throughput DAR monitoring for large sample sets
• DAR quantitation and monitoring with
compliance-ready software
Low-level
quantitation
Simple and fast-tracking of DAR
distribution using intact multiple
attribute methodology (intact MAM).
Learn about a solution for highthroughput DAR monitoring of a large
sample set. See how intuitive data
analysis software enables product
attribute definition, tracking and
quantitation with flexible custom
calculations for critical quality attributes
(CQAs) based on specific user needs.
Low-level sensitivity
Ultra-sensitive LC-MRM analysis for trastuzumabemtansine quantification in rat plasma.
Discover how an immunoaffinity-LC-MRM workflow enabled
the quantitation of trastuzumab-emtansine in rat plasma
at 1 ng/mL with high precision, accuracy and linearity. Learn
how the data was processed with SCIEX OS software—
an easy-to-use, compliance-ready software platform
for acquisition, processing and data management.
Average DAR of intact ADC and DAR of each payload results. (A) Average DAR
monitoring from each sample. (B) DAR monitoring of each payload result.
Calibration curve for trastuzumab-emtansine in rat plasma displayed with
log-log format. Concentrations range from 1 ng/mL to 20,000 ng/mL.
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Average DAR (Intact ADC)
1; Human_0hr、 、 2; Human_24hr 3; Human_48hr 4; Human_72hr
5; Monkey_0hr、6; Monkey _24hr 、7; Monkey _48hr 、8; Monkey _72hr
9; Mouse_0hr、10; Mouse _24hr 、11; Mouse _48hr 、12; Mouse _72hr
13; PBS_0hr、14; PBS _24hr 、15; PBS _48hr 、16; PBS _72hr
52 | sciex.com 53
Solution guide for pharmaceutical quantitation Introduction Discovery Development
(small mol)
Development
(large mol)
Regulatory
solutions
QA/QC and
lot release Products
Antibodies and
peptide surrogates
Simplify the quantitation of antibodies and peptide
surrogates. Confidently understand and quantify these
compounds, including low-abundance ions, faster than ever
before with easy-to-use, integrated software from SCIEX.
SCIEX software and solutions enable:
• Obtain high-quality, reliable data
• Confidently characterize and quantify antibodies and
peptide surrogates with robust, sensitive analyses
• Benefit from the support of experts eager
to help you improve your workflows and
move promising candidates forward
Surrogate peptide
quantitation
High sensitivity MRM workflow for
signature peptide quantification.
Read about an LC-MS option to
quantify peptides as surrogates
(bottom-up proteomic workflows)
using targeted LC-MRM. This approach
offers not only high sensitivity but
also a wide linear dynamic range (LDR)
combined with high reproducibility
to provide reliable quantitative.
Quantitation/ qualification
workflows
Simultaneous quantification of trastuzumab and pertuzumab
in humanserum using accurate mass spectrometry.
Discover a method for the sensitive quantitation of coadministered mAbs (trastuzumab and pertuzumab) in human
serum that allows for reduced sample volume requirements.
Sensitivity gains for peptide quantification
Summarized workflow for the simultaneous quantification of pertuzumab and trastuzumab in human serum.
54 | sciex.com 55
Solution guide for pharmaceutical quantitation Introduction Discovery Development
(small mol)
Development
(large mol)
Regulatory
solutions
QA/QC and
lot release Products
Biomarker quantitation
of large molecules
Discover better analytical solutions that meet
your needs for in-depth coverage with robust and
sensitive performance. Quickly and confidently
characterize and quantify large-molecule biomarkers
with intuitive SCIEX software that allows you to:
• Get confident answers in hours instead of days
• Confidently characterize and quantify large
biomarkers with robust, sensitive analyses
• Take advantage of dependable service support
Low-level
quantitation
Sensitive multiplexed quantification
of protein biomarkers for early drug
discovery and development.
Read about the sensitive quantitation
of surfactant proteins in plasma at
low-ng/mL levels. This technical note
demonstrates how to reach outstanding
accuracy, precision and linearity for
the quantitation of multiple protein
targets in complex matrices.
Quantitation/
qualification
workflows
Sensitive bioanalysis of galactosyl
sphingosine (GalSPH) and
glucosyl sphingosine (GluSPH)
in cerebral spinal fluid.
In this technical note, the method
sensitivity for 2 glycosphingolipids
(GluSPH and GalSPH) were evaluated
in cerebral spinal fluid. The assay was
developed using HILIC chromatography
and using positive MRM analysis
and electrospray ionization (ESI).
Extracted ion chromatograms were used for the quantification of hSFTP-A and hSFTP-D.
Extracted ion chromatograms of GluSPH and GalSPH.
56 | sciex.com 57
Solution guide for pharmaceutical quantitation Introduction Discovery Development
(small mol)
Development
(large mol)
Regulatory
solutions
QA/QC and
lot release Products
Cell culture
Comprehensive quantitation of the components in cell culture
media (CCM) is an important factor during the development
phases of biotherapeutic production. Often this analysis
requires the quantitation of over 100 analytes from various
compound classes, making it challenging to complete in a
single analysis. Our solutions can help by allowing you to:
• Acquire highly sensitive, selective and robust
data over a wide range of analytes
• Easily acquire, process and manage data with a
streamlined interface using SCIEX OS software
• Utilize expert service and support
to improve your workflows
Quantitative and
qualitative workflows
Enhanced sensitivity for cell
culture media analysis (CCMA).
The CCMA method demonstrated in this
technical note offers high sensitivity,
selectivity and robustness for the
identification and quantitation of over
110 compounds in a single analytical
method. The analysis was completed in
under 20 minutes with a 4x signal-tonoise (S/N) improvement on average. Demonstration of a 4-fold average S/N improvement, resulting in greater sensitivity.
A comprehensive method for
in-depth profiling of secreted
metabolites in cell culture media
from human adipose stem cells.
This technical note demonstrates
a sensitive profiling method for the
analysis of secreted metabolites in cell
culture media. Over 110 cell culture
metabolites were monitored in under
20 minutes using a single method
featuring fast polarity switching.
Overlapping MRM transitions were
optimized to maintain the maximum
dwell times and optimal cycle
times for accurate quantitation.
The Scheduled MRM Pro algorithm was used to optimize cycle times
and maximize dwell times for each MRM transition.
58 | sciex.com 59
Solution guide for pharmaceutical quantitation Introduction Discovery Development
(small mol)
Development
(large mol)
Regulatory
solutions
QA/QC and
lot release Products
Proteins
Tackle the next frontier in protein therapeutics with
analytical strategies ignited by collaboration. Our solutions
for comprehensive intact biotherapeutic analysis enable
confident selection of lead candidates during earlystage development and continued monitoring of product
quality attributes through to commercialization.
• Rapid screening without timeconsuming manual operations
• Intuitive data visualization for more
confident screening and selection
• Achieve consistent annotation of intact LC-MS data
Quantitative
Ultra-sensitive quantification of
intact insulin lispro in matrix.
In this technical note, a sensitive LCMRM method was developed for the
quantification of intact insulin lispro
in rat plasma using a simple sample
preparation strategy, requiring no
enrichment step. Robust quantification of
insulin lispro at 0.1 ng/mL in rat plasma.
Quantitative/
Qualitative workflows
Low-pg/mL quantitation of leucinerich repeat kinase 2 (LRRK2) protein
in human cerebrospinal fluid (CSF).
Investigate how a 2.5-fold improvement
in LLOQ and a 5-fold improvement in
signal-to-noise (S/N) can be achieved
by using microflow LC compared to
conventional analytical flow conditions.
Representative MRM XICs of insulin lispro in rat plasma. From left
to right: in matrix blank, at 0.05 ng/mL and 0.1 ng/mL.
Representative extracted ion chromatograms (XICs) for LRRK2 in human plasma.
Microflow LC conditions
LLOQ 25 pg/mL
S/N - 5
Analytical flow LC conditions 25 pg/mL
S/N – 24
5x gain in S/N
Microflow LC conditions LLOQ 10 pg/mL
S/N – 10
2.5x improvement in LLOQ
60 | sciex.com 61
Solution guide for pharmaceutical quantitation Introduction Discovery Development
(small mol)
Development
(large mol)
Regulatory
solutions
QA/QC and
lot release Products
Conclusion
Simplify your large molecule quantitative development
assays to save time and reduce the training needs
of the scientists working in your team. Our LC-MS
solutions—including our software and trusted services
and support team—are intuitive, robust and sensitive. A 2-fold revolution: MS approaches for the
bioanalysis of oligonucleotide therapeutics
In 1998, the US Food and Drug Administration
(FDA) approved fomivirsen as the first
oligonucleotide therapeutic. This approval
marked a revolution in drug development,
which then led to another revolution related to
analytical solutions: instruments that could keep
up with the ever-decreasing concentrations of
analytes in more potent drugs, which required
pushing the boundaries of sensitivity.
Rewrite the rules
In this vodcast series, we aim to
inspire not just you, but the entire
biopharmaceutical community. With
insights from leading scientists around
the world, it’s an invitation to reshape and
rewrite the rules of your laboratory.
Additional links for development assays
Antibody drug conjugate content pack
Take a deep dive into the characterization of
an antibody drug conjugate. Understand ADC
profiles regardless of the inherent heterogeneity
and high molecular weight of these molecules.
Featuring
• Instrument qualification
• Software validation
• Audit preparation
Regulatory
solutions
04
64 | sciex.com 65
Solution guide for pharmaceutical quantitation Introduction Discovery Development
(small mol)
Development
(large mol)
Regulatory
solutions
QA/QC and
lot release Products
Introduction
Achieving compliance in a regulated analytical laboratory is
a complex, time-consuming and costly journey that takes
you away from the day-to-day operations of your lab. We
offer compliance-ready solutions that help ensure your lab
produces compliant data without delaying your projects.
From qualified instrument installation and
system maintenance to compliant data reporting,
our team of compliance experts can guide
you through the complete process.
Compliance project timelines
Hardware qualification
Computer system validation
Months
All activities conducted by your personnel
Conducted by your personnel using SCIEX-provided documentation
All activities conducted by SCIEX
0 2 4 6 8 10 12
66 | sciex.com 67
Solution guide for pharmaceutical quantitation Introduction Discovery Development
(small mol)
Development
(large mol)
Regulatory
solutions
QA/QC and
lot release Products
Instrument
qualification
Our compliance products provide a complete solution for
instrument qualification—including LC, MS and LC-MS
systems and software—all at a fixed, predictable cost. This
can reduce the need for in-house expertise in regulatory
compliance. We complete the installation qualification
(IQ), operational qualification (OQ) and performance
qualification (PQ) work using good documentation practices
that are audit-ready, saving you both time and money.
Trained and certified SCIEX representatives
• Work with you to manage the qualification
process and simplify the experience
• Provide the knowledge and expertise you need to quickly
get your instrument ready for regulated laboratory work
• Execute services that will help minimize compliance
risk and provide you with peace of mind
Did you know?
SCIEX has delivered more than
10,000 qualifications and
over 1,000 validations without
any regulatory findings
68 | sciex.com 69
Solution guide for pharmaceutical quantitation Introduction Discovery Development
(small mol)
Development
(large mol)
Regulatory
solutions
QA/QC and
lot release Products
Software
validation
SCIEX provides software validation services that help ensure
your SCIEX OS software is properly configured for data integrity
and compliance with US FDA 21 CFR Part 11 regulations and
similar global standards. These services feature a complete
GAMP-5, V-model validation, including a validation plan,
risk assessment, requirements specification, configuration
specification, IQ/OQ/PQ protocols, traceability matrix, 21
CFR Part 11 assessment and validation summary report.
Software validation products include:
• Security and audit trail configuration
• Testing and confirmation of configurable settings
• Three tiers of service (essential, standard
and advanced) to fit every need
SCIEX OS software features for
compliance enable you to:
• Define and set appropriate permissions for your staff
• Set full traceability—including reasons,
e-signatures and time-stamped event logs—
using the audit configuration settings
• Generate printable reports
Did you know?
You can download and try any of our software
products for free to test in your workflow
70 | sciex.com 71
Solution guide for pharmaceutical quantitation Introduction Discovery Development
(small mol)
Development
(large mol)
Regulatory
solutions
QA/QC and
lot release Products
Audit preparations
Webinar: are you audit ready?
Topics covered in this webinar include:
• The top 5 things you need to do to meet
a typical audit requirement
• What auditors focus on (software/
hardware/documentation)
• The most commonly identified instances of non-compliance
SCIEX products and services give you peace
of mind when preparing for an audit:
• We have a proven record of successfully delivering
over 10,000 qualifications and 1,000 validations
• If auditors find any deficiency with our compliance
services, we will address the issue at no cost to you
• Our integrated test and validation plans enable
an efficient, streamlined audit process
• The consistent approach to style, content and purpose in
our report documentation provides clarity for auditors
72 | sciex.com 73
Solution guide for pharmaceutical quantitation Introduction Discovery Development
(small mol)
Development
(large mol)
Regulatory
solutions
QA/QC and
lot release Products
Conclusion
Partner with us to maintain your compliance
status in a timely and cost-efficient manner.
Compliance solutions can help ensure your lab produces
compliant data without delaying your projects. From
qualified instrument installation and system maintenance
to compliant data reporting, our team of compliance
experts can guide you through the complete process.
Additional links for regulatory support
The costly consequences of
unplanned downtime.
Unplanned downtime is a formidable adversary
that businesses across various industries
strive to minimize. Defined as the unexpected
interruption of regular operations, unplanned
downtime can wreak havoc on productivity,
profitability and customer satisfaction. In this
blog, we delve into the causes of unplanned
downtime, its far-reaching consequences
and strategies to mitigate its impact.
Easing the demands of a compliant
pharmaceutical laboratory.
While the performance of an analytical instrument
is an obvious requirement, we also understand that
developing a robust method is just the beginning.
In one of the most highly regulated industries, it is
no easy task to run a pharmaceutical laboratory
and satisfy all the relevant regulatory bodies
around the world. This blog shares how SCIEX
can help make this easier.heterogeneity and
high molecular weight of these molecules.
Are you audit ready?
Find out now!
Topics covered in this webinar include:
• The top 5 things you need to do to
meet a typical audit requirement
• What auditors focus on (software/
hardware/documentation)
• The most commonly identified
instances of non-compliance
Featuring
• Pharmaceutical impurities
• Nitrosamines
• Extractables and leachables
QA/QC and
lot release
05
76 | sciex.com 77
Solution guide for pharmaceutical quantitation Introduction Discovery Development
(small mol)
Development
(large mol)
Regulatory
solutions
QA/QC and
lot release Products
Introduction
Completing risk assessment, confirmation and implementation
of a control strategy for pharmaceutical impurities requires
assays that are accurate, sensitive and highly reproducible. We
aim to provide systems that make this as simple as possible.
We know that changes in the regulatory landscape
can present additional challenges to implementing
a robust quality management program.
Our solutions address these analytical challenges with fitfor-purpose hardware and compliant-ready software, all
maintained with industry-leading service and support.
Featured applications and assays
• Pharmaceutical impurities
• Nitrosamines
• Extractables and leachables
NDMA detected
in valsatan
NDMA detected
in piogltazone
FDA suspends
ranitidine (NDMA)
EMA suspends
ranitidine (NDMA)
FDA releases
NA impurities
guidance v1
NDMA detected
in metformin
Propranolol recalls
in Canada
Orphenadrine recalls
in the US
Health Canada
releases NA
impurities guidance v1
NDMA detected
in ranitidine
Nizatidine recalls
in the US (NDMA)
EMA releases
NA impurities
guidance V1
EMA
releases
FAQ v1
Varenicline recalls
and worldwide
distributin stop
by originator
Quinapril recalls
in the Us
ANVISA released
NA impurities
guidance v1
EMA publishes AIs for
NO_methylphenidate
NO_rasagiline,
NO_nortriptyline,
NTTP
EMA
introduces
option for
t- AI
during
remediation
06/2018 12/2018 06/2019 12/2019
06/2020
12/2020
06/2021
12/2021 06/2022
12/2022
Guidance
NDSRI
Small dialkyl nitrosamine
Featured solutions
Our portfolio of systems offers you the flexibility to select
the system that is right for your lab. The ExionLC AE system
offers reliable chromatography with minimal carryover and
is supported by our compliant-ready SCIEX OS software.
The MS system of choice is dependent on the sensitivity
of your assay, and potential requirements in the future.
Triple Quad 5500+ system offers robust
quantitative performance that meets the detection
requirements of most impurity analysis.
Triple Quad 6500+ system provides more sensitivity
for challenging analytes and matrices.
78 | sciex.com 79
Solution guide for pharmaceutical quantitation Introduction Discovery Development
(small mol)
Development
(large mol)
Regulatory
solutions
QA/QC and
lot release Products
Impurity
analysis
Identify, quantify and control impurities as efficiently as
possible using our systems for routine profiling and tracelevel analysis. Our integrated hardware and compliantready software solutions provide accurate impurity
detection with easy-to-use and learn workflows.
• Reliably identify, quantify and monitor nonintentionally added substances (NIAS)
• Understand the behavior of your packaged
product during manufacturing and storage
• Support your team with compliant-ready SCIEX OS software
Identification by
library matching
Impurity profiling of amiodarone stability samples using
accurate mass analysis and automated data processing.
Read about a routine, automated method for the
identification of drug impurities under basic and
oxidative conditions through library matching.
Quality control
Next generation quality control
in pharma applications.
Detect and quantify trace amounts
of critical impurities using the simple
and easy-to-use general unknown
comparative screening (GUCS) workflow
based on SWATH acquisition for accurate
impurity profiling and monitoring.
Identification of unknown peak in valsartan product.
Identification of amiodarone impurity D.
80 | sciex.com 81
Solution guide for pharmaceutical quantitation Introduction Discovery Development
(small mol)
Development
(large mol)
Regulatory
solutions
QA/QC and
lot release Products
Nitrosamines
Complete nitrosamine impurity analysis with confidence,
using fit-for-purpose triple quadrupole or highresolution systems that provide robust and sensitive
performance. Simplify this important analytical task
using SCIEX OS software, a compliant-ready software
for data acquisition, processing and reporting.
• Achieve robust and sensitive nitrosamine
detection and identification
• Benefit from trusted and reliable instrument
performance for nitrosamine analysis
• Simplify nitrosamine impurity analyses with
intuitive, compliant-ready software
Routine quantitation
Varenicline nitrosamine drug substancerelated impurity (NDSRI) quantification
in a varenicline drug product.
Using a simple sample preparation, a
robust and routine method was developed
for the quantitation of a nitroso-drug
substance-related impurity (NDSRI) in
a varenicline drug that provides a high
level of sensitivity and specificity.
Low-level quantitation
Low-level quantification of 10
mutagenic nitrosamine impurities
in Pioglitazone hydrochloride using
accurate mass spectrometry.
Discover how fast scanning enables the
simultaneous quantitation of multiple
nitrosamine impurities with exceptional
quantitative performance below the
current recommended limit (30 ng/g) in a
Pioglitazone hydrochloride drug product.
Representative extracted ion chromatogram (XIC) for 10 nitrosamines
and UV chromatogram for Pioglitazone hydrochloride.
Quantification of varenicline NDSRI in a varenicline drug product.
82 | sciex.com 83
Solution guide for pharmaceutical quantitation Introduction Discovery Development
(small mol)
Development
(large mol)
Regulatory
solutions
QA/QC and
lot release Products
Extractables
and leachables
Find the perfect fit for your team with compliant-ready
extractables and leachables (E&L) analysis solutions designed
for your laboratory. We have developed E&L analysis solutions
alongside our customers with ease-of-use in mind.
• Simpler method setup helps optimize lab investments
• Sensitive methods deliver analytical
results your team can trust
• Compliant-ready software allows you to easily
control and manage your processes
E&L identification
Confident identification in extractable
and leachable screening.
Discover how an open-access E&L
high-resolution MS/MS spectral library
can be used to search and identify
compounds across a breadth of E&L
compound classes for both targeted
and non-targeted screening.
Low-level detection
Comprehensive workflow for
sensitive detection and confident
identification of extractable and
leachable (E&L) impurities.
Read about a comprehensive
and sensitive workflow for a
high-resolution LC-MS/MS E&L
method using library matching.
Recommended molecular formula and identified structure
for m/z 428.3124 using SCIEX OS software and ChemSpider.
Obtain confident identification through the SCIEX open access
extractables and leachables high resolution MS/MS spectral library.
RT= 4.15 min ME= 0.3 ppm Acquired
Library
C11H22N2O3
84 | sciex.com 85
Solution guide for pharmaceutical quantitation Introduction Discovery Development
(small mol)
Development
(large mol)
Regulatory
solutions
QA/QC and
lot release Products
Conclusion
We understand your quality needs.
• With fit-for-purpose solutions, SCIEX can help you better
understand and ensure the safety of your products from
early development to lot release. Our solutions enable
reliable identification, quantitation and monitoring of NIAS.
• Our service team and suite of service tools can
help you maintain the qualification status of your
systemand ensure your system is running at its best.
Additional resources
Overcome N-nitrosamine analysis
challenges with chromatographic and
mass spectrometry techniques
Learn how the QTRAP 6500+ system equipped
with a SelexION device were combined with a
carefully selected chromatographic column
to enable a simplified sample preparation
workflow for the identification of nitrosamines.
Accurate mass extractables & leachables open
access high resolution MS/MS spectral library
Download the open-access accurate mass
library for E&L species that contains high
quality high resolution spectra for relevant
chemical species and moieties allowing for
automated simultaneous ID and quantitation.
Overcoming N-nitrosamine analysis
challenges with mass spectrometry and
chromatography solutions - SCIEX Community
Three key analytical components must
work together for the most sensitive and
accurate nitrosamine impurity detection:
mass spectrometry, chromatography
and sample preparation.
What have we learned from the
nitrosamine crisis? - SCIEX Community
The background and history driving the
evolving regulatory landscape around
genotoxic impurities are discussed.
Extractables and leachables analysis
SWATH Acquisition with a SCIEX X500R QTOF
system enables fast detection and quantitation
of E&L substances using SCIEX library searching
and ChemSpider matching of MS/MS data.
Featuring
• Triple quadrupole systems
• Quadrupole time-of-flights systems
• Echo® MS+ system
• Service and software
Products
06
88 | sciex.com 89
Solution guide for pharmaceutical quantitation Introduction Discovery Development
(small mol)
Development
(large mol)
Regulatory
solutions
QA/QC and
lot release Products
Performance, features and sensitivity
SCIEX Triple Quad
4500 system
SCIEX 5500+
system
SCIEX Triple Quad
6500+ system
SCIEX 7500+
system
Ideal
applications
• Nitrosamines
• Extractables and
leachables
• Impurity and
degradant analysis
• Nitrosamines
• Extractables and
leachables
• Impurity and
degradant analysis
• Small molecule
bioanalysis
• Biomarker quantitation
• Lead identification
• Drug metabolism and
pharmacokinetics (DMPK)
• Small molecule biomarker
quantitation
• Targeted protein
degraders (TPDs)
• Trace-level lead
identification
Example data Analysis of nitrosamine
compounds in multiple
sartan APIs: a review
and optimization of the
Ph. Eur. monograph
Highly selective and
sensitive method
for quantification of
nitrosamines in valsartan
drug substances
High sensitivity
quantification of triptorelin
deca peptide using the
QTRAP® 6500 system
Redefine bioanalysis with
enhanced robustness on
the SCIEX 7500+ system
MS
specifications
• Sensitivity (MRM
mode)*: S/N >300,000
• Scan speed: 12,000
Da/second
• Mass range: 5–2,000 m/z
• Sensitivity (MRM
mode)*: S/N >750,000
• Scan speed: 12,000
Da/second
• Mass range: 5–1,250 m/z
• Sensitivity (MRM mode)*:
S/N >1,500,000
• Scan speed: 12,000
Da/second
• Mass range: 5–2,000 m/z
• Sensitivity (MRM mode)*:
S/N > 5,000,000
• Scan speed: 12,000
Da/second
• Mass range: 5–2,000 m/z
Triple quadrupole
systems
The ExionLC AE system provides reproducibility, reliability
and carryover performance to match your quantitative
workflows. You can count on it’sdependability, from
injection to injection and batch after batch.
When combined with a SCIEX Triple Quad LC-MS/MS system
there is no stopping you with their modern, robust and
straightforward designs. These systems enable scientists to
acquire multiple reaction monitoring (MRM), precursor, neutral
loss and product ion scans to develop powerful methods for
complex matrices, all while maintaining reproducibility and
robustness. All are QTRAP-ready for enhanced scan functions
offering method flexibility to provide the data you need.
*Reserpine, 1 pg on column with electrospray ionization in positive ion mode (ESI+)
90 | sciex.com 91
Solution guide for pharmaceutical quantitation Introduction Discovery Development
(small mol)
Development
(large mol)
Regulatory
solutions
QA/QC and
lot release Products
Performance, features and sensitivity
X500R QTOF system ZenoTOF 7600 system
Ideal
applications
• Extractables and leachables
• MetID (routine)
• Nitrosamines (with LC separation challenges)
• Pharmaceutical impurities
• Biomarker quantitation (complex matrices)
• Biomarker quantitation (large molecules)
• DMPK (quant/qual workflows)
• MetID (with challenging analytes)
• Oligo MetID/biotransformations
• Targeted protein degraders (quant/qual workflows)
Example data Analysis of nitrosamine impurities in a metformin
drug substance and drug product
Confident identification of phase 1 metabolites
using electron-activated dissociation (EAD)
MS
specifications
• Sensitivity (MRM mode)*: S/N >750
• Scan speed: 42,000 FWHM at m/z 956
• Mass range: TOF up to 40 KDa
• Sensitivity (MRM mode)*: S/N >2,500
• Scan speed: 42,000 FWHM at m/z 956
• Mass range: TOF up to 40 KDa
Quadrupole timeof-flight systems
Boost performance and productivity in your lab with
quadrupole time-of-flight (QTOF) mass spectrometry
systems for qualitative and quantitative analysis. Whether
you need the most comprehensive coverage and workflow
flexibility to take on new projects or a simplified and easyto-use system for routine testing analyses, the SCIEX QTOF
portfolio delivers unmatched speed, robustness and accuracy
for the assays you need to run today and tomorrow.
*Reserpine, 1 pg on column with electrospray ionization in positive ion mode (ESI+)
92 | sciex.com 93
Solution guide for pharmaceutical quantitation Introduction Discovery Development
(small mol)
Development
(large mol)
Regulatory
solutions
QA/QC and
lot release Products
Echo® MS+ system
When the quantity of samples is your challenge, break
through with the Echo® MS+ system. Echo® MS+ system
gives you high-quality data, analytical flexibility and high
sample throughput to help you make the right decisions
today. With ejection rates of up to 1 sample/second, you
can get results on the same day they are submitted to
your lab. The Echo® MS+ system is a complete solution
that removes bottlenecks in high-throughput analytical
workflows, from sample preparation to data reporting.
Echo® MS+ system with
ZenoTOF 7600 system
High-res targeted screening:
• HTS: small molecule
• HTS: intact proteins
Additional benefits:
• Reduce background interference with
increased specificity and selectivity
• Ease of method development (MS method)
Echo® MS+ system with SCIEX
Triple Quad 6500+ system
Best suited for absolute sensitivity for quantitative work:
• Absolute sensitivity for quantitative work:
• HTS: biochemical assays
Additional benefits:
• Simplicity of general system operation
• Higher level of quantitative consistency
Performance, features and sensitivity
94 | sciex.com 95
Solution guide for pharmaceutical quantitation Introduction Discovery Development
(small mol)
Development
(large mol)
Regulatory
solutions
QA/QC and
lot release Products
Software
and services
SCIEX OS software
Software to power your SCIEX ecosystem
Discover an integrated software platform solution for
all SCIEX innovations. SCIEX OS software delivers data
integrity, seamless usability and efficiency gains for
your mass spectrometry workflows throughout your
laboratory. Built on advanced and sophisticated algorithms,
SCIEX OS software facilitates instrument control and
automated data processing, simplifying your workflows
and empowering swift, well-informed decision-making.
LC-MS service and support plans
Keep your workflows running and your
instruments performing at peak levels with LCMS service and support plans from SCIEX.
Choose the plan option that best meets your response time,
repair coverage and maintenance needs, and benefit from:
• Increased productivity
• Maximum uptime
• SCIEX technical expertise
• Total workflow support
Lab compliance services
Achieving compliance in a regulated analytical laboratory is
a complex, time-consuming and costly journey that takes
you away from the day-to-day operations of your lab.
SCIEX offers compliance solutions that help ensure your
lab produces quality data without delaying your projects.
From start to finish, our team of compliance experts can
guide you through the complete process, enabling you to:
• Improve productivity
• Reduce costs
• Get expert advice
• Maintain best practices
Manage your SCIEX ecosystem >
96 | sciex.com 97
Solution guide for pharmaceutical quantitation Introduction Discovery Development
(small mol)
Development
(large mol)
Regulatory
solutions
QA/QC and
lot release Products
Conclusion
SCIEX LC-MS/MS solutions are designed to
simplify the processes required to accelerate
the analysis of pharmaceuticals, their potential
impurities, and biological processes.
We will support your team with a simple-to-use single
software platform that is compliant-ready.
SCIEX has the quantitative solutions to address
the challenges regularly faced by scientists,
along with potential solutions for your lab.
The SCIEX clinical diagnostic portfolio is For In Vitro Diagnostic Use. Rx Only. Product(s) not available in all countries. For information on availability,
please contact your local sales representative or refer to www.sciex.com/diagnostics. All other products are For Research Use Only. Not for use in
Diagnostic Procedures. Trademarks and/or registered trademarks mentioned herein, including associated logos, are the property of AB Sciex Pte.
Ltd. or their respective owners in the United States and/or certain other countries (see www.sciex.com/trademarks). AB Sciex™ is being used under
license. Empower is a trademark of Waters Corporation used under license. NanoAssemblr® is a trademark of Precision NanoSystems (part of Cytiva).
Biozen™Oligo LC column is a trademark of Phenomenex. © 2025 DH Tech. Dev. Pte. Ltd. MKT-30685-A.
Headquarters
500 Old Connecticut Path, Framingham, MA 01701 USA
Phone 508-383-7700
sciex.com
International Sales
For our office locations please call the division
headquarters or refer to our website at
sciex.com/offices
SCIEX Nowsupport network
SCIEX Now
• Manage your instruments.
• Submit and manage support cases,
track status and view history.
• Access online training courses and articles.
• Manage software licenses linked
to your registered instruments.
• View and report critical instrument
statistics when connected to StatusScope
remote monitoring service.
• Be a part of the SCIEX community by
submitting questions and comments.
• Receive notifications from SCIEX with
content based on your preferences.
SCIEX Now learning hub
• SCIEX Now learning hub success
programs provide LC-MS and CE training
customized to meet your exact needs.
• With a selection of training methods and
certifications available, you can build
a mass spectrometry program that is
most suited to your lab and users.
• Starting with a clear understanding of
your desired learning outcomes, we aim
to help you improve lab productivity
and consistency by designing and
delivering a program that is focused on
knowledge advancement and retention.
Brought to you by

Download the How To Guide for FREE Now!
Information you provide will be shared with the sponsors for this content. Technology Networks or its sponsors may contact you to offer you content or products based on your interest in this topic. You may opt-out at any time.
Experiencing issues viewing the form? Click here to access an alternate version