Highly Accurate HCV Genotyping by Targeted Next Generation Sequencing
Poster Dec 22, 2016

Kok Siong Poon, Evelyn S. Koay, Cui Wen Chua, Mui Joo Khoo, Zhang Rui, Elian Rakhmanaliev, Wen Huang, Gerd Michel
Determination of HCV genotype (GT) provides essential information for decision making on treatment regimens in HCV infection. DNA hybridization employing a line probe test format (VERSANT HCV Genotype 2.0 LiPA), first introduced about 20 years ago, still represents the most widely used laboratory method. The recent fast advancement of next generation sequencing (NGS) technologies allowing for unprecedented speed and accuracy in analyzing viral genomes are opening new ways to further improve diagnostic genotyping of HCV.
We have used NGS in combination with workflow automation, from sample preparation to result reporting, to demonstrate high accuracy of GT assessment in clinical samples. This newly developed platform based on a customized version of the epMotion 5075 robotic system (Eppendorf, Germany) consists of a continuous robotic process starting with plasma or serum extraction and RT-PCR followed by automated library preparation, Ion Torrent deep sequencing and direct online data analysis to determine HCV GTs. In contrast to the commonly used 5’UTR region, the limitations of which are well recognized, we have employed target sequences from the HCV NS3, NS5A and NS5B regions. Results were compared to line probe assay data obtained from the same samples. Randomly selected archived serum or plasma samples from 143 Asian and 7 African patients with chronic HCV infection, viral loads ranging from 5.50x102 to 1.04x108 IU/mL (median 6.10x106), were included in the study. GT distribution was as follows: 11 GT1a, 14 GT1b, 12 GT2, 58 GT3, 9 GT4, 7 GT5, and 39 GT6. In 16/150 (11%) of the samples, discordant results between the two methods were obtained. Confirmation testing by Sanger sequencing indicated that the ability to discriminate at the major GT level was 89.3% (95%CI: 83.4 – 93.3) for VERSANT and 100% (95%CI: 97.5-100) for NGS. Correct GT subtype calls were found to be 89% for VERSANT and 100% for NGS. Among the 16 discordant samples, 8 GT6 were erroneously classified as GT1b by line probing, 6 GT3 as GT4, and another 2 GT3 as GT6.
In conclusion, considering the crucial role of correct genotyping in HCV treatment management, workflow automated HCV NGS appears as a highly reliable tool for differentiating HCV GTs, which can help to prevent diagnostic errors potentially leading to suboptimal treatment.
Not least, the library generated DNA contigs are fully user accessible for further sequence analysis thereafter, e.g., enabling assessment of additional mutations specific to the case under investigation. This additional feature may prove useful for monitoring resistance to novel drug treatments.
This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License

OTHER POSTERS
When there is a need to quickly analyze samples using a number of different PCR assays, it is likely that optimal conditions for each assay will not be the same. First, different assays often will require different annealing temperatures for their primers. In addition, amplicons may be designed to be of different lengths and therefore require varying durations of the extension step.
READ MORELike what you just read? You can find similar content on the communities below.
Diagnostics Genomics ResearchTo personalize the content you see on Technology Networks homepage, Log In or Subscribe for Free
LOGIN SUBSCRIBE FOR FREE