As PFAS regulations evolve and environmental monitoring programs expand, laboratories face growing pressure to accurately detect, quantify, and characterize these persistent contaminants across diverse sample matrices.
While LC-MS/MS remains the foundation of regulatory testing, a broader analytical toolkit is increasingly needed to address volatile compounds, emerging PFAS, unknown fluorinated substances, and real-time monitoring requirements.
This listicle explores six analytical approaches shaping modern PFAS monitoring, highlighting their strengths, applications, and roles in supporting comprehensive environmental assessment and remediation efforts.
Download this listicle to discover:
How LC-MS/MS, GC-MS, and HRMS support targeted and non-targeted PFAS monitoring strategies across environmental samples.
The role of ion mobility spectrometry, total fluorine methods, and precursor analysis in revealing PFAS beyond standard target lists.
Emerging technologies and complementary approaches that can strengthen environmental monitoring and remediation programs
1
The Expanding PFAS Toolkit:
Six Methods Driving
Environmental Monitoring
Alexander Beadle
Poly- and perfluoroalkyl substances (PFAS) are synthetic compounds that are extremely resistant to
heat, water, oil, and other common degradation mechanisms. As a result, these chemicals readily accumulate
in the environment where they can remain for hundreds of years, earning them the moniker
"forever chemicals."
In the past, the extreme stability of these forever chemicals made these compounds attractive for use
in firefighting foams, non-stick cookware, and water-repellent fabrics. However, in recent decades,
scientific investigations have uncovered associations between exposure to specific PFAS and adverse
health effects, including altered immune function, liver and kidney disease, reproductive health concerns,
and cancer.
In light of these findings, many regulators are responding to these potential harms with more stringent
rules on PFAS production and use, as well as launching PFAS monitoring and remediation programs to
track and act on the spread of these chemicals in the environment.
With PFAS contamination already being widespread in waterways, soils, and the air, appropriately monitoring
PFAS contamination requires a toolbox-like approach, with many different analytical techniques
supporting monitoring efforts. This listicle will explore the techniques that are central to PFAS regulatory
testing, as well as the additional analytical approaches that can provide complementary information for
PFAS analysis and quantitation.
1. Liquid chromatography–tandem mass spectrometry:
The gold standard for PFAS monitoring
Liquid chromatography–tandem mass spectrometry (LC–MS/MS) is the most established technique used
for PFAS monitoring, from a regulatory perspective. In the United States, the US Environmental Protection
Agency (EPA) issues a list of standard analytical methods for PFAS analysis that have been validated and
can be used to support regulatory activities. Analysis via LC–MS/MS forms the backbone of EPA Methods
537 and 533, targeting PFAS analysis in drinking water (in line with the Safe Drinking Water Act), and in
Methods 8327 and 1633 for measuring PFAS in non-potable water and solid waste (in line with the Clean
Water Act and Resource Conservation and Recovery Act).
Listicle
THE EXPANDING PFAS TOOLKIT: SIX METHODS DRIVING ENVIRONMENTAL MONITORING 2
To deal with this wide array of different sample matrices, LC–MS/MS is frequently combined with
pre-treatment or other sample preparation techniques. This often includes the use of solid-phase extraction
(SPE) or ion-exchange SPE to enhance the method's selectivity, sensitivity, and clean-up of target
analytes from background. SPE is of particular interest in PFAS environmental monitoring as, under the
right conditions, SPE materials can enable "passive sampling" approaches in which PFAS load is measured
over days or weeks. This type of approach offers better sensitivity for low-level PFAS and can
provide a valuable time-weighted average of PFAS concentrations in the environment that is less affected
by periodic fluctuation.
Depending on the application, it may also be useful to employ multiple reaction monitoring—also known
as selected reaction monitoring—to selectively detect and quantify specific PFAS mixtures. This can help
with the monitoring of trace PFAS in complex matrices, which would otherwise be difficult to analyze.
Using high-performance liquid chromatography (HPLC) or ultra-high-performance liquid chromatography
(UHPLC) in conjunction with tandem mass spectrometry can also be used where exceptionally low limits
of detection and high sensitivity are required, such as in contamination control.
2. Gas chromatography–mass spectrometry:
Monitoring volatile PFAS
While being less effective for non-volatile and high-molecular weight compounds such as long-chain
PFAS, gas chromatography–mass spectrometry (GC–MS) can be a highly effective way to monitor volatile
PFAS in the air.
For example, while the majority of the US EPA's standard analytical methods make use of LC–MS/MS for
the analysis of non-volatile and semi-volatile PFAS, Other Test Method (OTM)-50 relies on GC–MS to measure
30 known volatile PFAS in air emissions from stationary sources. This may include emissions from
chemical manufacturers, commercial applications, and thermal treatment incineration processes, which
can be trapped in air canisters and tested using the OTM-50 method.
While not routinely used for regulatory efforts, levels of volatile PFAS present in water or other aqueous
samples can also be monitored through the use of headspace SPE GC–MS. This can be used in complement
to LC–MS/MS methods for water monitoring, as the GC–MS method requires significantly less
sample preparation and thus introduces minimal sources for contamination and analytical error.
3. High-resolution mass spectrometry:
Expanding beyond target lists
The majority of PFAS monitoring efforts that come from a regulatory lens are "targeted" methods, meaning
that they are concerned with the presence of specific, known compounds. In contrast, "non-targeted"
(or "untargeted") methods are used for detecting and measuring the semi-quantitative abundance of all
detectable molecules in a substance, including unknown compounds.
Non-targeted analysis (NTA) plays a key role in PFAS discovery and can be used to highlight emerging
PFAS of concern in environmental and biological samples.
Due to its extremely high mass accuracy—typically within 1–5 ppm—high-resolution mass spectrometry
(HRMS) is able to determine exact molecular formulas with a high degree of confidence, allowing for the
identification of unknown compounds. As of a 2019 review, NTA approaches based on HRMS have been
used to discover more than 750 PFAS belonging to more than 130 chemical classes in a broad range of
different sample matrices, including biofluids, environmental samples, and commercial products.
Listicle
THE EXPANDING PFAS TOOLKIT: SIX METHODS DRIVING ENVIRONMENTAL MONITORING 3
While NTA methods are not typically used for routine environmental monitoring, the identification of
emerging PFAS or PFAS breakdown products is a crucial step in improving monitoring efforts; as new
compounds of concern are identified through semi-quantitative methods such as HRMS, these can then
be added to the target lists used in targeted PFAS monitoring if analytical standards already exist for
these compounds, or standards can begin to be developed.
In PFAS analysis, HRMS/MS is also sometimes used to improve molecular structure predictions when
characterizing unknown analytes. A subset of NTA, suspect screening compares molecular features
against large databases to identify potential matches and can also improve confidence in structural proposals
where this is needed.
4. Ion mobility spectrometry–mass spectrometry:
Improving PFAS separation
Chromatography techniques are often coupled with mass spectrometry in order to separate matrix components
from the sample analytes and to improve overall sensitivity. However, there are alternatives to
chromatographic methods that can also be used for PFAS analysis.
In ion mobility spectrometry–mass spectrometry (IMS), the sample is ionized and sent through a drift
tube to be separated according to their charge and mass, but also according to how the ions interact with
a buffer gas flowing in the opposite direction to the ion stream. Highly charged ions and/or smaller ions
will move more quickly through the apparatus, while bulky ions will be slowed through their collision with
the gas molecules.
This separation method can easily be nested into existing GC and LC–MS workflows. It can also be a
useful complement to LC–MS/MS data, as the use of this different separation mechanism provides an
additional dimension of information about the analyte molecules; because the time that an analyte spends
in IMS is determined largely by effective physical area (also known as the "collision cross section" of an
ion), this may help to identify unknowns and distinguish between chemical isomers which share the same
molecular weight but have very different molecular structures.
IMS–MS has been increasingly applied in PFAS analysis over the past several years. A number of studies
have demonstrated the effective use of the technique for the rapid characterization of PFAS in environmental
water samples. Another example, this time a study of passive samplers in aquatic environments
near a fluorochemical manufacturer in North Carolina, found that IMS–MS was able to identify 36
known PFAS as well as elucidate 8 new PFAS species that had previously gone unreported in environmental
media.
5. Total fluorine and organofluorine methods:
Measuring the unknown fraction
All of the analysis methods above are "direct" or "specific" methods for PFAS measurement—meaning
that they are concerned with looking at individual compounds. In contrast, "indirect" or "non-specific"
methods focus less on detecting and quantifying individual PFAS and instead consider the total PFAS load
in a sample.
Listicle
THE EXPANDING PFAS TOOLKIT: SIX METHODS DRIVING ENVIRONMENTAL MONITORING 4
Examples of indirect fluorine testing commonly applied in PFAS monitoring include:
• Total fluorine: Measures the sum of all forms of fluorine present in a sample.
• Total organic fluorine (TOF): Measures only organic (carbon-bound) fluorine, while ignoring natural
minerals containing fluorine salts.
• Extractable organofluorine (EOF): Similar to TOF, but instead of analyzing a complete raw sample, it
is only able to capture the portion of organic fluorine that extracts into a solvent; this is often required
for solid samples, tissues, or very complex matrices.
• Absorbable organic fluorine: Similar to EOF, but for the screening of organic fluorine compounds
dissolved in water.
Each of these methods measures a slightly different fraction of the total fluorine load, though the general
idea is the same—to use fluorine as a proxy for estimating the total PFAS concentration in a sample. The
majority of these analyses are performed using combustion ion chromatography, with particle-induced
gamma-ray emission and high-resolution continuum source graphite furnace molecular absorption spectrometry
being the two next-most common techniques.
In a similar fashion, the total oxidizable precursor (TOP) assay offers another way to capture a broader
array of PFAS compounds. Many of the unmeasured PFAS in direct methods are PFAS precursors, which
may exist in the environment before being converted into PFAS through oxidation. The TOP assay helps to
capture this fraction of compounds in aqueous samples by oxidatively converting PFAS precursor compounds
into perfluorocarboxylic acids. By comparing this to the initial sample, it is possible to estimate
the concentration of PFAS precursors present in samples such as industrial effluent, landfill leachate, and
other environmental sites of interest.
6. Sensor systems: Real-time monitoring for rapid response
Sensor-based solutions for PFAS monitoring are an emerging technology, geared towards enabling fast
and portable in-field testing. While LC–MS/MS remains the gold standard for PFAS analysis, it requires
laboratory infrastructure and operation by highly trained personnel; in contrast, the optical, electrochemical,
and biosensing systems currently being developed for PFAS monitoring can deliver a simple result
(such as a visible color change) for rapid environmental monitoring.
However, there are still many significant barriers facing the commercialization and routine adoption of
sensors for PFAS monitoring. The majority of these technologies are highly specific, meaning that they
will only respond to one specific PFAS analyte. Additionally, many of the current sensors still have relatively
high detection limits that render them unsuitable for measuring the ultra-low PFAS concentrations
that are relevant to regulatory efforts.
Listicle
THE EXPANDING PFAS TOOLKIT: SIX METHODS DRIVING ENVIRONMENTAL MONITORING 5
The outlook on environmental PFAS monitoring
PFAS monitoring is an essential aspect of protecting human and animal health, as well as a key part of
guiding environmental remediation efforts.
LC–MS/MS is a core technique for PFAS monitoring, largely due to its extreme sensitivity. As a
result, LC–MS/MS forms the backbone of regulatory testing approaches targeting the analysis of PFAS
in environmental samples. Where a more comprehensive view of PFAS load is needed, or where LC–MS/
MS is limited in its applicability, experts can turn to a wider analytical toolbox—including techniques such
as GC–MS and HRMS—which may be more suitable for analyzing certain sample types or for studying
emerging PFAS of concern.
More novel technologies, such as sensor systems, may one day further support this toolbox by allowing
for more flexible in-field testing. Unlike traditional laboratory techniques, these systems may be more
easily integrated into monitoring programs to enable more frequent PFAS testing and to facilitate the
early identification of PFAS hotspots in the environment.
Sponsored by
About the author:
Alexander is a science writer and editor for Technology Networks. He writes news and features for the Applied Sciences and
Analysis & Separations communities, leading the site's coverage of topics relating to environmental science, food and beverage
analysis, and analytical techniques. Before joining Technology Networks, Alexander worked as a freelance science writer. He holds
a masters degree in Materials Chemistry from the University of St Andrews, Scotland.
Listicle
Sponsored by
Shimadzu CorporationShimadzu is a world-leading manufacturer of analytical instrumentation. In every corner of the world, their products and services are being used by customers to develop a variety of new products to protect and restore the environment and deliver better health and lifestyles to people. With pride in these achievements firmly in mind, they strive to improve their technologies further and enhance their knowledge so that they can offer even greater technologies, products and services.
Information you provide will be shared with the sponsors for this content. Technology Networks or its sponsors may contact you to offer you content or products based on your interest in this topic. You may opt-out at any time.