No Bleeding Required: Anemia Detection via Smartphone

Listen with
Speechify
0:00
Register for free to listen to this article
Thank you. Listen to this article using the player above.

Want to listen to this article for FREE?

Complete the form below to unlock access to ALL audio articles.

Read time: 2 minutes

Biomedical engineers have developed a smartphone app with the aim of non-invasive detection of anemia. Instead of a blood test, the app uses photos of someone’s fingernails taken on a smartphone to determine whether the level of hemoglobin in their blood seems low.

The results were published on Tuesday, Dec. 4 by Nature Communications.

“All other ‘point-of-care’ anemia detection tools require external equipment, and represent trade-offs between invasiveness, cost, and accuracy,” says principal investigator Wilbur Lam, MD, PhD. “This is a standalone app that can look at hemoglobin levels  without the need to draw blood.”

Lam is a clinical hematologist-bioengineer at the Aflac Cancer and Blood Disorders Center of Children’s Healthcare of Atlanta, associate professor of pediatrics at Emory University School of Medicine and a faculty member in the Wallace H. Coulter Department of Biomedical Engineering at Georgia Tech.

The app is part of the PhD work of former biomedical engineering graduate student Rob Mannino, PhD, who was motivated to conduct the research by his own experience living with beta-thalassemia, an inherited blood disorder caused by a mutation in the beta-globin gene.

“Treatment for my disease requires monthly blood transfusions,” Mannino says. “My doctors would test my hemoglobin levels more if they could, but it’s a hassle for me to get to the hospital in between transfusions to receive this blood test. Instead, my doctors currently have to just estimate when I’m going to need a transfusion, based on my hemoglobin level trends.”

“This whole project couldn’t have been done by anyone but Rob,” Lam says. “He took pictures of himself before and after transfusions as his hemoglobin levels were changing, which enabled him to constantly refine and tweak his technology on himself in a very efficient manner. So essentially, he was his own perfect initial test subject with each iteration of the app.”

Mannino and Lam say that their app could facilitate self-management by patients with chronic anemia, allowing them to monitor their disease and to identify the times when they need to adjust their therapies or receive transfusions, possibly reducing side effects or complications of having transfusions too early or too late.

The researchers say that the app should be used for screening, not clinical diagnosis. The technology could be used by anyone at any time, and could be especially appropriate for pregnant women, women with abnormal menstrual bleeding, or runners/athletes. Its simplicity means it could be useful in developing countries. Clinical diagnostic tools have strict accuracy requirements, but Mannino and Lam think that with additional research, they can eventually achieve the accuracy needed to replace blood-based anemia testing for clinical diagnosis.

Anemia is a blood condition that affects two billion people worldwide and can lead to fatigue, paleness and cardiac distress if left untreated. The current gold standard for anemia diagnosis is known as a complete blood count (CBC).

The researchers studied fingernail photos and correlated the color of the fingernail beds with hemoglobin levels measured by CBC in 337 people: some healthy, and others with a variety of anemia diagnoses. The algorithm for converting fingernail color to blood hemoglobin level was developed with 237 of these subjects and then tested on 100.

The researchers were able to show that a single smartphone image, without personalized calibration, can measure hemoglobin level with an accuracy of 2.4 grams/deciliter with a sensitivity of up to 97 percent. Personalized calibration, tested on four patients over the course of several weeks, can improve the accuracy to 0.92 grams/deciliter, a degree of accuracy on par with point-of-care blood-based hemoglobin tests. Normal values are 13.5-17.5 grams/deciliter for males and 12.0-15.5 grams/deciliter for females.

In the app, the use of fingernail beds, which do not contain melanin, means the test can be valid for people with a variety of skin tones. The accuracy is consistent for dark or light skin tones, Mannino says. The app uses image metadata to correct for background brightness, and can be adapted to phones from multiple manufacturers.

Mannino and Lam say they are working with a variety of doctors at Children’s and Emory – geriatric, internal medicine, neonatologists, transfusion medicine, global health – to obtain additional data and better calibrate their system.

“This is just a snap shot of the accuracy right now,” Lam says. “The algorithm gets smarter with every patient enrolled.”

This article has been republished from materials provided by Emory University. Note: material may have been edited for length and content. For further information, please contact the cited source.

Reference:

Mannino, R. G., Myers, D. R., Tyburski, E. A., Caruso, C., Boudreaux, J., Leong, T., . . . Lam, W. A. (2018). Smartphone app for non-invasive detection of anemia using only patient-sourced photos. Nature Communications, 9(1). doi:10.1038/s41467-018-07262-2